6.2.1.5.3
Phase Modulation (PM)
What the settings
are for
In the case of phase modulation the information is contained in the phase
changes to the output signal. The amplitude of the output signal stays
constant. The amplitude of the modulation signal is contained within the size
of the phase change (phase deviation) in the output signal. The frequency of
the modulation signal is contained in the frequency of the phase change in
the output signal.
You can use the PM MOD submenu to set the PM modulation signal,
modulation frequency and phase deviation.
Selecting the
PM MOD
submenu
•
In the
submenu
press the
function key
.
The submenu is opened and the function keys [13] are assigned the
appropriate function.
Exit submenu
Set modulation frequency
( 6-124)
Set phase deviation
( 6-124)
Select modulation signal
( 6-123)
Switch modulation on/off
( 6-125)
PM FREQ
PM WAVEFORM
Signal carrier
Modulated signal