Operation in Receiver Mode
R&S FSH
1145.5973.12 2.22
E-11
Direct entry of a channel table:
!
If the channel display is active (CHANNEL MODE softkey active in the FREQ menu), press the
CHANNEL TABLE softkey.
!
Press the SELECT USER TAB softkey.
The R&S FSH will use the last channel table that was entered directly.
!
Press the DEFINE USER TAB softkey.
The R&S FSH will open the submenu for defining the
channel table.
!
Press the DEFINE USER TAB softkey again.
!
Enter the number of the first channel and confirm with the ENTER key.
!
Press the DEFINE USER TAB softkey.
!
Using the rotary knob or the cursor keys, select 1
ST
CHANNEL FREQ... from the menu and confirm
with the ENTER key.
!
Enter the frequency for the first channel number.
!
Press the DEFINE USER TAB softkey.
!
Using the rotary knob or the cursor keys, select NO OF CHANNELS... from the menu and confirm
with the ENTER key.
!
Enter the number of channels and confirm with the ENTER key.
!
Press the DEFINE USER TAB softkey.
!
Using the rotary knob or the cursor keys, select CHANNEL SPACING... from the menu and confirm
with the ENTER key.
!
Enter the frequency spacing for the channels and confirm with the ENTER key.
!
Press the EXIT key to exit the menu for defining channel tables.
The R&S FSH will now show channel numbers rather than the frequency. It also shows the associated
frequency above Channel.
Selecting the reference level:
The reference level is the maximum level of the analog bar-graph display. It must be set such that the
level display is located within the bar-graph scale.
!
Press the REF LEVEL softkey in the main menu of the receiver mode (MEAS key). Or press the
AMPT key.
!
Using the rotary knob or cursor keys, change the reference level or, using the numeric keys, enter a
new reference level.
!