CTS60
Remote Control/Annex C
1094.0006.60 C.17
E-5
9. Menu:
Timing
Pass/Fail Verdict for Time Accuracy
Syntax:
CALCulate:LIMit:TIME:ACCuracy:TOLerance:MATChing?
Return:
(MATC | NMAT | INV)
State:
DCE
Option:
none Only query
Note:
Returns the result of the last measurement (N10), (N12)
Time Accuracy
Syntax:
Execute new measure-
ment and signal result
Only read result
READ[:SCALar]:TIME:ACCuracy?
FETCh[:SCALar]:TIME:ACCuracy?
Return:
<Value> (Unit:
ppm)
State:
DCE
Option:
none Only query
Note:
(N10)
Pass / Fail Verdict for Jitter
Syntax:
CALCulate:LIMit:JITTer:TOLerance:MATChing?
Return:
(MATC | NMAT | INV), (MATC | NMAT | INV)
State:
DCE
Option:
none Only query
Note:
Returns the result of the last measurement, the first value is the
positive value, the second is the negative one, (N10), (N12)
Jitter
Syntax:
Execute new measure-
ment and signal result
Only read result
READ[:SCALar]:JITTer?
FETCh[:SCALar]:JITTer?
Return:
<Value>, <Value>
(Unit: sec)
State:
DCE
Option:
none Only query
Note:
The first value is the positive value, the second is the negative one,
(N10)