Interfaces/Annex A
CTS60
1094.0006.60
A.4
E-2
Cable for local controller coupling in the case of hardware handshake
The connection of the CTS to a controller is effected with a so-called zero modem cable. In the case of
this cable, the data, control and report lines must be crossed. The following wiring diagram applies to a
controller with 9-pin or 25-pin configuration.
CTS
Controller
CTS
Controller
9-pin 9-pin
9-pin 25-pin
1
2
3
4
5
6
7
8
9
------------RxD / TxD---------------
------------TxD / RxD---------------
------------DTR /DSR--------------
------------GND / GND-------------
------------DSR / DTR--------------
------------RTS / CTS--------------
------------CTS / RTS--------------
1
3
2
6
5
4
8
7
9
1
2
3
4
5
6
7
8
9
------------RxD / TxD---------------
------------TxD / RxD---------------
------------DTR /DSR--------------
------------GND / GND-------------
------------DSR / DTR--------------
------------RTS / CTS--------------
------------CTS / RTS--------------
8
2
3
6
7
20
5
4
22
Fig. A3-3
Wiring of the data, control and report lines for hardware handshake