Electronic Code Locks SL2000B v1.4 and SL200S1K v1.3 EN Rev.C.doc
2011-11-16
Strona 5 z 13
Commands
Commands can be entered during normal working time of a SL2000 and doesn’t require
entry to the programming mode.
[USER Code] [#]
Whenever a valid USER code is entered the code lock generates two beeps (**) and then
starts count
C1C2
time delay. After it passes SL2000 activates Door Lock (momentary)
output for the time defined by
C3C4
settings.
[MASTER Code] [#]
Each time the MASTER code is entered the SL2000 changes its arming mode (switches
from Armed to Disarmed mode or in reverse direction).
[INSTALLER Code] [#]
After this command code lock generates two beeps (**) and enters the Installer
Programming mode. In this mode installer can manage (add, modify or delete) the USER
codes.
[*][Old INSTALLER Code][#][New INSTALLER Code] [#]
This command erases the current INSTALLER code and program a new one. If command
is successfully accomplished the unit generates three series of two beeps (** ** **)
[*] [Old MASTER Code] [#][Old MASTER Code] [#]
This command erases the current MASTER code and program a new one. If command is
successfully accomplished the unit generates three series of two beeps (** ** **).
[#]
Normally pressing [#] is used to mark the end of the code but when pressed separately
for a time longer the 0.5s it triggers Door Bell indication.
Programming The USER Codes
The SL2000 enables programming of up to 55 different USER codes. The USER codes can
be managed (added/deleted/changed) only in the Installer Programming mode (to enter
Installer Programming mode press: [INSTALLER Code]+[#]). Once in the Installer
Programming mode you have following commands:
[0] [1] [#] [code] [# ]
; Programming of the USER code no. 1
[0] [2] [#] [code] [#]
; Programming of the USER code no. 2
… etc.
… etc.
… etc.
[5] [5] [#] [code] [#]
; Programming of the USER code no. 55
[0] [0] [#]
; Delete all USER codes
[9] [9] [#][code][#]
; Deletes the code entered in square brackets
[#]
; Exit from the Installer Programming mode
When the SL2000 accepts the new USER code it generates two series of two beeps (**
**). Any attempt to program the USER code which already exists in the memory or to
program it with a wrong length then will cause the programming error signaled by a long
acoustic beep.
Note: Whenever you re-program MASTER or INSTALLER code remember that new code
programmed into a unit must have the same length as the old one.
Summary of Contents for SL2000B
Page 1: ...Roger Sp j Electronic Code Locks SL2000B v1 4 and SL2000S1K v1 3 Document version Rev C ...
Page 9: ...Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Strona 9 z 13 ...
Page 10: ...Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Strona 10 z 13 ...
Page 11: ...Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Strona 11 z 13 ...