Special options 

Timed Lock-Out  

If this option is enabled the Sl2000 disables the keypad for 60 seconds after three 
attempts of entry of the  incorrect code. After this time the SL2000 re-enables the 
keypad and is ready to accept new keypad’s entries. The end of 60 seconds lock-out time 
is indicated by two series of two beeps (**  **). 

Disable USER Codes When in Armed Mode  

If this option is enabled the SL2000 grants access only when it operates in Disarmed 
mode. With this option active the access to the controlled door will be totally disabled 
unless the SL2000 will be switched to Disarmed mode again. Thanks to this formula the 
MASTER user can disable access to the room by switching the unit to the Armed mode 
and vice verso, he can re-enable access to the controlled door by switching the lock to 
the Disarmed mode. The SL2000 can be switched between Armed and Disarmed modes 
via the MASTER code only. 

Codes 

The SL2000 offers three types of codes: 

 

MASTER Code 

 

INSTALLER Code 

 

USER Codes 

Each type of code is dedicated for individual purpose. The length of each code can be 
programmed during Memory Reset procedure. The entry of each code must be followed 
by the [#] key which is used to mark the end of the code. 
MASTER Code 
The MASTER code is used to switch the SL2000 between Armed and Disarmed modes, it 
can be 4-10 digits long.  

INSTALLER Code 

The INSTALLER code is required to enter the Installer Programming mode, it can be 4-10 
digits long. 

USER Codes 

These codes are used solely to trigger the Door Lock (momentary) output. Each time a 
valid USER code is entered the SL2000 starts counting 

C1C2

 time delay and then 

activates Door Lock output for time defined by the 

C3C4

 parameters. The USER codes 

can be 2-8 digits long. 

Note: If you are not going to use a door open sensor leave the Door Contact input 

unconnected. Without a door open sensor the SL2000 will not signal the 

Door Alarm

Note: When the SL2000 is in Armed mode this output remains not active (red 

CLOSE 

LED

   lights up), it become active when lock works in Disarmed mode(green 

OPEN LED

 

 lights up). 

Note: The SL2000 enables programming of maximum 55 USER codes, each of them can 

be used to trigger  Door Lock output. 

Summary of Contents for SL2000B

Page 1: ...Roger Sp j Electronic Code Locks SL2000B v1 4 and SL2000S1K v1 3 Document version Rev C ...

Page 2: ... two transistor outputs Bistable Switch i Bell Relay output The REL output offers one switched NO NC contact rated 1 5A 30V AC DC This output is activated each time a user code sequence is entered User code 01 55 Activation takes place after a C1C2 delay and lasts for the time specified by the C3C4 parameter Each time the RELAY switch of SL2000 lock is activated the yellow led ENTRANCE lights up B...

Page 3: ... maximum voltage applied to it must not exceed 15VDC Normally the Aux output is used to trigger some kind of warning device e g alarm siren or buzzer Door Alarm The Door Alarm will occur when door has been opened without entering of a valid USER code door has been opened without pressing of the Exit Button door has not been closed within designated time defined by the C5C6 configuration settings O...

Page 4: ...es of codes MASTER Code INSTALLER Code USER Codes Each type of code is dedicated for individual purpose The length of each code can be programmed during Memory Reset procedure The entry of each code must be followed by the key which is used to mark the end of the code MASTER Code The MASTER code is used to switch the SL2000 between Armed and Disarmed modes it can be 4 10 digits long INSTALLER Code...

Page 5: ...de and program a new one If command is successfully accomplished the unit generates three series of two beeps Normally pressing is used to mark the end of the code but when pressed separately for a time longer the 0 5s it triggers Door Bell indication Programming The USER Codes The SL2000 enables programming of up to 55 different USER codes The USER codes can be managed added deleted changed only ...

Page 6: ...to normal work it enters Armed mode Meaning of the configuration parameters C1 C10 C1C2 Specifies the time delay from a moment when USER code is entered till moment when Door Lock output will be triggered It can be programmed from 00 to 99s default 04 C3C4 Specifies the time for which Door Lock output will be activated It can be programmed from 02 to 99s default 04 C5C6 Specifies the time within d...

Page 7: ...1 C10 digits once again The Memory Reset procedure automatically comes to an end when the last C10 digit is entered The device stores the configuration as well as all codes in a nonvolatile memory which can be reprogrammed whenever required After the Memory Reset procedure comes to an end all codes are set to factory default values see section below Default Codes Example The following digits C1 C1...

Page 8: ...or outdoor location SL2000B can be installed in indoor location only Assure that the surface beneath of the controller s rear panel is flat and smooth Disconnect power supply before making any electrical connections Once installed and electrically connected the unit has to be properly programmed When forgotten MASTER and INSTALLER codes can be restored to their default values and then programmed a...

Page 9: ...Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Strona 9 z 13 ...

Page 10: ...Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Strona 10 z 13 ...

Page 11: ...Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Strona 11 z 13 ...

Page 12: ...AC Technical Specification Parameter Value Supply 10 15 VDC Current consumption Avg 25 mA 12V DC Max 80 mA 15V DC with relay output active Anti sabotage protection Tamper NC contact 50mA 24V Environmental Class SL2000B Class II input temp 10 C 40 C relative humidity 0 75 SL2000S1K Klasa IV outdoor general temp 25 C 60 C relative humidity 0 95 Dimensions W x S x G SL2000B 105 X 104 X 30 mm SL2000S1...

Page 13: ...67 01 26 e mail support roger pl Web www roger pl The symbol of a crossed through waste bin on wheels means that the product must be disposed of at a separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be taken to a collection point for recycling electrical and...

Reviews: