Electronic Code Locks SL2000B v1.4 and SL200S1K v1.3 EN Rev.C.doc 

2011-11-16 

 
 

 

 

Strona 2 z 13

 

 
 
 

Features 

 

Bell

 output to indicate Door Bell and Door Alarm 

 

Bistable/Switch

 output to control door locking device   

 

DC input for detection of door status  

 

DR input to unlock the door from the external button  

 

INSTALLER code for programming  

 

MASTER code switch between armed and disarmed modes 

 

55 USER codes for door unlocking 

 

Programmable length of codes 

 

User indexing for easy administration of the codes 

 

Nonvolatile memory 

 

Three LEDs and buzzer 

 

Tamper 

 

12VDC supply 

 

CE 

Introduction 

The SL2000 electronic code lock is dedicated to operate as a stand-alone door access 
control unit. It is equipped with one relay output, two transistor outputs and three inputs. 
All codes and parameters programmed to device are stored in nonvolatile memory. 
SL2000S1K is located in metal enclosure and can operate in outdoor locations.  

Functional Description 

Output 

SL2000 has one relay output  and two transistor outputs (Bistable/Switch i Bell).  

Relay output 

The REL output offers one switched NO/NC contact rated 1.5A/30V AC/DC. This output is 
activated each time a user code sequence is entered (User code 01..55). Activation takes 
place after a 

C1C2

 delay and lasts for the time specified by the 

C3C4

 parameter. Each 

time the RELAY switch of SL2000 lock is activated the yellow led 

ENTRANCE

 

 

 lights up. 

By using the Main code it is possible to temporary disable/enable activity of all user 
codes (Disable USER Codes When in Armed Mode). 

Open collector outputs 

The Bistable (Switch in SL2000B) and BELL outputs of SL2000 lock are an open collector 
transistor type. Some care must be taken in order to protect them from damage. When 
transistor output is switched off it remains in high impedance state, when switched on it 
shorts connected to it potential with supply minus. The maximum current must not 
exceed 1A and maximum voltage must not exceed 15VDC. 

Note: The C1,C2…C10 parameters which appear in this manual refer to the configuration 
parameters programmed to the SL2000 during 

Memory Reset

 procedure (for details see 

section: Configuring the SL2000 later in this document).  

Summary of Contents for SL2000B

Page 1: ...Roger Sp j Electronic Code Locks SL2000B v1 4 and SL2000S1K v1 3 Document version Rev C ...

Page 2: ... two transistor outputs Bistable Switch i Bell Relay output The REL output offers one switched NO NC contact rated 1 5A 30V AC DC This output is activated each time a user code sequence is entered User code 01 55 Activation takes place after a C1C2 delay and lasts for the time specified by the C3C4 parameter Each time the RELAY switch of SL2000 lock is activated the yellow led ENTRANCE lights up B...

Page 3: ... maximum voltage applied to it must not exceed 15VDC Normally the Aux output is used to trigger some kind of warning device e g alarm siren or buzzer Door Alarm The Door Alarm will occur when door has been opened without entering of a valid USER code door has been opened without pressing of the Exit Button door has not been closed within designated time defined by the C5C6 configuration settings O...

Page 4: ...es of codes MASTER Code INSTALLER Code USER Codes Each type of code is dedicated for individual purpose The length of each code can be programmed during Memory Reset procedure The entry of each code must be followed by the key which is used to mark the end of the code MASTER Code The MASTER code is used to switch the SL2000 between Armed and Disarmed modes it can be 4 10 digits long INSTALLER Code...

Page 5: ...de and program a new one If command is successfully accomplished the unit generates three series of two beeps Normally pressing is used to mark the end of the code but when pressed separately for a time longer the 0 5s it triggers Door Bell indication Programming The USER Codes The SL2000 enables programming of up to 55 different USER codes The USER codes can be managed added deleted changed only ...

Page 6: ...to normal work it enters Armed mode Meaning of the configuration parameters C1 C10 C1C2 Specifies the time delay from a moment when USER code is entered till moment when Door Lock output will be triggered It can be programmed from 00 to 99s default 04 C3C4 Specifies the time for which Door Lock output will be activated It can be programmed from 02 to 99s default 04 C5C6 Specifies the time within d...

Page 7: ...1 C10 digits once again The Memory Reset procedure automatically comes to an end when the last C10 digit is entered The device stores the configuration as well as all codes in a nonvolatile memory which can be reprogrammed whenever required After the Memory Reset procedure comes to an end all codes are set to factory default values see section below Default Codes Example The following digits C1 C1...

Page 8: ...or outdoor location SL2000B can be installed in indoor location only Assure that the surface beneath of the controller s rear panel is flat and smooth Disconnect power supply before making any electrical connections Once installed and electrically connected the unit has to be properly programmed When forgotten MASTER and INSTALLER codes can be restored to their default values and then programmed a...

Page 9: ...Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Strona 9 z 13 ...

Page 10: ...Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Strona 10 z 13 ...

Page 11: ...Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Strona 11 z 13 ...

Page 12: ...AC Technical Specification Parameter Value Supply 10 15 VDC Current consumption Avg 25 mA 12V DC Max 80 mA 15V DC with relay output active Anti sabotage protection Tamper NC contact 50mA 24V Environmental Class SL2000B Class II input temp 10 C 40 C relative humidity 0 75 SL2000S1K Klasa IV outdoor general temp 25 C 60 C relative humidity 0 95 Dimensions W x S x G SL2000B 105 X 104 X 30 mm SL2000S1...

Page 13: ...67 01 26 e mail support roger pl Web www roger pl The symbol of a crossed through waste bin on wheels means that the product must be disposed of at a separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be taken to a collection point for recycling electrical and...

Reviews: