Reader should be installed in such way as to ensure physical access to the connection
cable, screw terminals and programming jumpers.
Before the reader will be mounted in desired location it is recommended to configure its
operating mode and if required to program the MASTER and INSTALLER users.
Any MIFARE proximity card can be programmed as MASTER or INSTALLER card.
When lost or stolen a new MASTER and INSTALLER cards (PIN-s) can be reprogrammed in
the reader.
When the reader has been set for
Terminal Mode
(online unit connected to the host
controller), programming of MASTER and INSTALLER users can be skipped.
A new factory delivered unit is configured with
[000] Online mode, RACS address
ID=0
.
The reader should be mounted near the supervised door on a vertical piece of supporting
structure.
Disconnect power supply before making any electrical connections.
Be aware that the installation of reader directly on the metal type surface will reduce card
reading distance.
For installations on a metal surface you can place a non-metallic 10 mm thick spacer (a
plastic/plaster plate etc.) between the reader and the supporting structure.
For installations with two readers to be mounted on the opposite sides of the same wall and
aligned along the same geometrical axis, place a metal plate between them and make sure
none of two readers has direct contact with it (allow min. 10 mm space). Be aware that the
reading distance will be reduced.
For best results mount the proximity readers at least 0.5 m apart.
When using separate power supply sources, short all power supply negatives (ground).
It is recommended to ground the negative power supply line (only at one point).
Summary of Contents for PRT MF Series
Page 47: ...PRTxxMF series readers Operating Manual doc 2019 01 29 47 54 ...
Page 48: ...PRTxxMF series readers Operating Manual doc 2019 01 29 48 54 ...
Page 49: ...PRTxxMF series readers Operating Manual doc 2019 01 29 49 54 ...
Page 50: ...PRTxxMF series readers Operating Manual doc 2019 01 29 50 54 ...
Page 51: ...PRTxxMF series readers Operating Manual doc 2019 01 29 51 54 ...
Page 52: ...PRTxxMF series readers Operating Manual doc 2019 01 29 52 54 ...
Page 53: ...PRTxxMF series readers Operating Manual doc 2019 01 29 53 54 ...