PRTxxMF series readers Operating Manual.doc
2019-01-29
20/54
302
Tamper Alarm
Reader entered
Tamper Alarm
state
303
Intruder Alarm
Reader entered
Intruder Alarm
state
305
Duress Alarm
Reader entered
Duress
Alarm
state
999
Unknown event
Event code doesn’t fit any known event – error in data
5.13.
R
EAL
T
IME
C
LOCK
The reader is equipped with Real Time Clock (RTC) predefined for 100 year. This clock is used to
append a time stamp to every event recorded by the reader. The RTC clock has not battery back-
up so it resets to 2000-01-01 00:00 whenever power is off. When required, the RTC can be
configured to switch automatically to winter or summer time.
Note: When reader’s Real Time Clock is unset (or lost due to lack of power supply) reader
continues its operation however this can be changed. When option
Real Time Clock Control
is
enabled then the reader will stop its operation till the clock is programmed again (see Installer
Programming, function
[78]
.
5.14.
T
IMERS
Reader uses several timers, each timer is assigned to specific function and can be programmed in
seconds or minutes.
ID
Timer
Defaults
Function
0
Door Unlock Time
(00-99 sec./min.)
4 s
Defines time for which door lock will be released.
This timer controls following outputs:
[41]: Door
Lock
,
[42]: Door Lock Exit
,
[43]: Door Lock
Entry.
Programming time 00s makes that timer
counts down for unlimited period and it is stopped
upon next access is granted again (toggle mode).
1
Door Open Timeout
(00-99 sec./min.)
12 s
Determines time in which door should be closed.
Door Open Timer
starts from the moment when
Door Lock Time
has passed out.
2
AUX1
(00-99 sec./min.)
2 s
Defines duration time for output
[50]: AUX1
Momentary.
Programming timer to 00s makes
that timer counts down for unlimited period till
moment when reader changes it arming mode.
3
AUX2
(00-99 sec./min.)
2 s
Defines duration time for output
[51]:
AUX2
Momentary.
Programming timer to 00s makes
that timer counts down for unlimited period till
moment when reader changes it arming mode.
4
Pulse on Arming
(01-99 sec./min.)
2 s
Defines duration time for output
[52]: Pulse on
Arming.
5
Pulse on Disarming
(01-99 sec./min.)
2 s
Defines duration time for output
[53]: Pulse on
Disarming.
6
Pulse
on
Arming/disarming
(01-99 sec./min.)
2 s
Defines duration time for output
[54]: Pulse on
Arming/disarming
output.
7
Tamper Alarm
(00-99 sec./min.)
60 min
Defines duration time for
Tamper Alarm
.
Programming timer to 00s makes that timer
counts down for unlimited period till moment
when reader changes it arming mode.
Summary of Contents for PRT MF Series
Page 47: ...PRTxxMF series readers Operating Manual doc 2019 01 29 47 54 ...
Page 48: ...PRTxxMF series readers Operating Manual doc 2019 01 29 48 54 ...
Page 49: ...PRTxxMF series readers Operating Manual doc 2019 01 29 49 54 ...
Page 50: ...PRTxxMF series readers Operating Manual doc 2019 01 29 50 54 ...
Page 51: ...PRTxxMF series readers Operating Manual doc 2019 01 29 51 54 ...
Page 52: ...PRTxxMF series readers Operating Manual doc 2019 01 29 52 54 ...
Page 53: ...PRTxxMF series readers Operating Manual doc 2019 01 29 53 54 ...