PRTxxMF series readers Operating Manual.doc
2019-01-29
24/54
secondary (slave) reader. The LED/buzzer signals occur simultaneously on both readers (primary
and secondary). Both readers must have the same supply minus. It is not required to disconnect
the XM-2 expander from system being currently programmed.
6.2.
P
ROGRAMMING VIA
M
EMORY
C
ARD
The configuration settings of the reader can be exported to and imported from a special
Memory
Card
(
M-Card
). The
M-Card
is the standard MIFARE 4k proximity card specially formatted by the
RARC program for this purpose. Reader settings can be exported to
M-Card
from a reader or from
the RARC program. Also, the reader settings saved on the
M-Card
can be imported directly from
M-Card
to the reader or to the RARC program.
Note: The communication between RARC program and
Memory Card
can be provided through any
PRTxxMF series reader connected to the PC.
The entire settings of the reader can be divided into three parts:
User settings
Installer settings
Configuration settings (complete)
The
Configuration settings
refers to all parameters programmed into a reader (card, PIN-s and
all other data). The
Users settings
refers to settings which are solely related with users (cards
and PIN-s) while
Installer settings
refers to the rest of reader settings (i.e. all configuration data
except cards and PIN-s). Following rule applies:
Configuration settings = User se Installer settings
6.2.1.
Importing Configuration Settings from the Memory Card
This procedure imports reader settings (Users Data + Installer Data) from the Memory Card.
Switch power supply off
Remove all connections from CLK and DTA lines
Connect CLK to DTA
Switch power on
Wait till LED SYSTEM is on
Wile LED SYSTEM is on disconnect CLK from DTA
Wait till LED STATUS
starts blinking red
While LED STATUS
is blinking red place M-Card very close to the front of the reader
and keep it in this position
Once LED STATUS
stops blinking remove the M-Card, reader will make restart and
then will enter normal operation with new settings imported from the M-Card
6.2.2.
Exporting Configuration Settings to the Memory Card
This procedure exports reader settings (Users Data + Installer Data) to the Memory Card.
Switch power supply off
Remove all connections from CLK and DTA lines
Connect CLK to DTA
Switch power on
Wait till LED SYSTEM is on
Wile LED SYSTEM is on disconnect CLK from DTA
Wait till LED STATUS
starts blinking green
While LED STATUS
is blinking green place M-Card very close to the front of the
reader and keep it in this position
Once LED STATUS
stops blinking remove the M-Card, reader will make restart and
then will enter normal operation, the Configuration Settings from the reader were
exported to the M-Card
6.2.3.
Importing Users Data from Memory Card
This procedure imports Users Data (cards and PIN-s) from the Memory Card.
Summary of Contents for PRT MF Series
Page 47: ...PRTxxMF series readers Operating Manual doc 2019 01 29 47 54 ...
Page 48: ...PRTxxMF series readers Operating Manual doc 2019 01 29 48 54 ...
Page 49: ...PRTxxMF series readers Operating Manual doc 2019 01 29 49 54 ...
Page 50: ...PRTxxMF series readers Operating Manual doc 2019 01 29 50 54 ...
Page 51: ...PRTxxMF series readers Operating Manual doc 2019 01 29 51 54 ...
Page 52: ...PRTxxMF series readers Operating Manual doc 2019 01 29 52 54 ...
Page 53: ...PRTxxMF series readers Operating Manual doc 2019 01 29 53 54 ...