PRTxxMF series readers Operating Manual.doc
2019-01-29
18/54
Note: The
Forced Entry
and
Door Ajar
alarms can occur only if the reader operates with a door
open sensor connected to the input with function
[21]: Door Contact
.
5.8.
T
AMPER
A
LARM
This alarm is dedicated to indicate that reader circuit is tampered and it is triggered by external
detector connected to reader’s input configured with the function
[26]: Tamper
. The alarm is
operated independently from internal tamper switch which is activated by reader’s enclosure
opening or detachment from the place of installation.
Tamper Alarm
can be raised either in armed
or disarmed mode. Once this alarm emerges reader starts counting
Tamper Timer
and activates
outputs with functions
[55]: Tamper Alarm
and/or
[57]: General Alarm
(if programmed). When
Tamper Timer
is counted down then reader disables
[26]: Tamper
input thus protecting the
reader from multiple tamper alarms. The
Tamper Alarm
ceases automatically when
Tamper
Timer
elapses or reader changes its arming mode.
5.9.
I
NTRUDER
A
LARM
This alarm is dedicated to indicate that intruder is penetrating area protected with sensor
connected to reader’s input
[27]: Intruder
or door was opened in unauthorized method (
Forced
Entry
). The
Intruder Alarm
can be raised in armed mode only. Once this alarm emerges reader
starts counting
Intruder Timer
and activates outputs with functions
[56]: Intruder Alarm
and/or
[57]: General Alarm
(if programmed). When
Intruder Timer
is counted down then
reader disables
[27]: Intruder
input thus protecting the reader from multiple intruder alarms.
This alarm ceases automatically when
Intruder Timer
elapses or reader changes its arming mode.
5.10.
D
URESS
A
LARM
Reader can be configured to recognize and signal entering of the PIN code under duress. When
option
Duress Alarm
is enabled reader will treat PIN code as under duress when the last digit of
the entered PIN code differs by +/- 1 from the original one. The
Duress Alarm
can be indicated on
the output with function
[60]: Duress Alarm
while the signalling time can be adjusted by
Duress
Alarm Timer
. This alarm ceases automatically when
Duress Timer
elapses or reader changes its
arming mode.
5.11.
G
ENERAL
A
LARM
This alarm is a sum of two separate alarms:
Tamper Alarm
and
Intruder Alarm
and it is
triggered whenever one of them is raised.
General Alarm
can be indicated on the output line with
function
[57]: General Alarm
while the signalling time can be adjusted by
General Alarm
Timer
. This alarm ceases automatically when
General Alarm Timer
elapses or reader changes its
arming mode.
5.12.
E
VENTS
R
ECORDING
Reader is capable to record several types of events with their time stamps. Events are stored in
cyclic (FIFO) buffer – when entire event memory is occupied reader removes oldest events to
releases space for the new ones to come. The reader can record up to 1000 events.
List of events
Code
Event Name
Description
100
Access granted
Access for the user (ID + name) has been granted
Pause - 5 s
any
valid
identifier
or
disappears automatically after
3 minutes. Also, closing door
immediately clears this alarm.
Note: Modulation methods are used for both, the output line and for internal buzzer as well (if
configured for alarm indication).
Summary of Contents for PRT MF Series
Page 47: ...PRTxxMF series readers Operating Manual doc 2019 01 29 47 54 ...
Page 48: ...PRTxxMF series readers Operating Manual doc 2019 01 29 48 54 ...
Page 49: ...PRTxxMF series readers Operating Manual doc 2019 01 29 49 54 ...
Page 50: ...PRTxxMF series readers Operating Manual doc 2019 01 29 50 54 ...
Page 51: ...PRTxxMF series readers Operating Manual doc 2019 01 29 51 54 ...
Page 52: ...PRTxxMF series readers Operating Manual doc 2019 01 29 52 54 ...
Page 53: ...PRTxxMF series readers Operating Manual doc 2019 01 29 53 54 ...