PRTxxMF series readers Operating Manual.doc
2019-01-29
22/54
Acoustic Signals
Signal
Symbol
Description
One long signal
-
Error - unknown identifier, access denied.
Three
short
beeps
* * *
Command successfully completed (OK signal).
Two short beeps
* *
Prompt signal, the reader is waiting for the next
part of the command to be entered. This signal is
intended to encourage the programmer to proceed
with next programming steps.
Long
beep
continuously
repeated
- - - - - - …
Reader has detected problem (either configuration
memory is corrupted and reader must be
reconfigured anew). This signal is accompanied by
the steady lit LED SYSTEM .
Legend: - long beep, * beep
5.16.
O
PERATION WITH
XM-2
I/O
E
XTENSION
M
ODULE
In
Full Standalone Mode
, reader requires connection with XM-2 I/O extension module. Each input
and output of the XM-2 can be programmed on the same basis as internal inputs and outputs of
the reader. The XM-2 should be connected to the reader’s CLK and DTA lines and must have
address set to ID=5. The maximum distance between the reader and XM-2 extension module is
limited to 150 m.
Note: The XM-2 module has two red LED-s which are intended to indicate triggering of
corresponding relay output (REL1 or REL2) and one green LED which lights continuously when
communication with host reader is working and blinking when broken.
5.17.
O
PERATION WITH
S
ECOND
PRT
S
ERIES
R
EADER
In
Full Standalone Mode,
the main PRTxxMF reader can operate with second PRT series reader,
even when it works with another card standard (e.g. EM 125 KHz). The access system with two
readers using different card technologies can be used for installations with two card technologies.
The second PRT reader should be connected with main (primary) reader and configured for
RACS
address ID=0
. The pair of two readers can be used for two way door control or for programming
purpose when the main reader is not equipped with keypad. The maximum distance between
primary and secondary PRT reader is limited to 150 m.
Note: The LED-s and buzzer on secondary reader mimics (imitate) the LED-s/buzzer on primary
reader.
6 .
P
R O G R A M M I N G
The reader can be programmed:
From the PC with RARC program (RS232)
From the keypad located on the main reader
From the keypad located on the external (secondary) reader
Through multiple reading of the so called
Programming Card
By configuration export/import via MIFARE card
Preparing the Reader for Terminal Mode (Online mode)
If the unit is dedicated for
Terminal Mode
(slave operation), then it is only necessary to program
[000]..[003] operating mode but in most cases default RACS mode with ID=0 address is sufficient.
Operating mode can be programmed manually during
Memory Reset
or remotely from PC.
Summary of Contents for PRT MF Series
Page 47: ...PRTxxMF series readers Operating Manual doc 2019 01 29 47 54 ...
Page 48: ...PRTxxMF series readers Operating Manual doc 2019 01 29 48 54 ...
Page 49: ...PRTxxMF series readers Operating Manual doc 2019 01 29 49 54 ...
Page 50: ...PRTxxMF series readers Operating Manual doc 2019 01 29 50 54 ...
Page 51: ...PRTxxMF series readers Operating Manual doc 2019 01 29 51 54 ...
Page 52: ...PRTxxMF series readers Operating Manual doc 2019 01 29 52 54 ...
Page 53: ...PRTxxMF series readers Operating Manual doc 2019 01 29 53 54 ...