PRTxxMF series readers Operating Manual.doc
2019-01-29
34/54
This timer defines duration time for pulse generated on
[53]
function output. Program S=0 for
seconds or S=1 for minutes.
[85][S][KL] – Programming “Pulse on Arming/Disarming” timer, S=0..1, KL=01..99,
default: S=0 KL=02
This timer defines duration time for pulse generated on
[54]
function output. Program S=0 for
seconds or S=1 for minutes.
[#] - Exit from Installer Programming mode
Reader leaves
Installer Programming
mode and returns to normal operation (either Armed or
Disarmed) depending on the state it was before.
Note: If you don’t press any key for 1 min then reader will automatically leave the
Installer
Programming
mode.
8.2.
I
NPUT
/
OUTPUT
F
UNCTIONS
Input/output Functions
Code
Name
Description
11
Line Off
Line is disabled and reader ignores electrical states on this
line.
21
Door Contact
Input, when shorted with supply minus indicates that
controlled door is closed.
22
Exit Button
Input, shorting this line with supply minus triggers
[41]:
Door Lock
and
[42]: Exit Door Lock
outputs (when
programmed) for time specified by
Door Unlock Time.
This
input doesn’t activate
[43]: Entry Door Lock
.
23
Arming Disabled
Input, as long as line is shorted with supply minus reader
disables TOGGLE and TOGGLE LTD user from switching the
reader into
Armed
mode.
24
Arming/Disarming
Key Switch
Input, when line is shorted to supply minus reader switches
unconditionally to
Disarmed
mode, when line is open reader
returns and stay in
Armed
mode.
25
LED STATUS
Input, when programmed it controls LED STATUS
and this
LED no longer presents current arming mode of the reader.
When line is shorted to supply minus LED STATUS
lights in
green, when open lights in red.
26
Tamper
Input, normally closed, opening this input (no matter in
Armed
mode or in
Disarmed
mode) will start
Tamper
Alarm
and
General Alarm
.
27
Intruder
Input, normally closed to supply minus, opening this input
during
Armed
mode will start
Intruder Alarm
and
General
Alarm.
28
Buzzer Control
Input, when shorted with supply minus activates buzzer.
29
LED OPEN Control
Input, when shorted with supply minus activates LED OPEN.
41
Door Lock
Output, whenever access is granted (no matter from primary
or secondary or through exit button), this output is triggered
for time specified by
Door Unlock Time
.
42
Exit Door Lock
Output, triggered whenever access is granted from primary
(main) reader or by triggering of the
[22]: Exit Button
input, once triggered it goes on for time specified by
Door
Summary of Contents for PRT MF Series
Page 47: ...PRTxxMF series readers Operating Manual doc 2019 01 29 47 54 ...
Page 48: ...PRTxxMF series readers Operating Manual doc 2019 01 29 48 54 ...
Page 49: ...PRTxxMF series readers Operating Manual doc 2019 01 29 49 54 ...
Page 50: ...PRTxxMF series readers Operating Manual doc 2019 01 29 50 54 ...
Page 51: ...PRTxxMF series readers Operating Manual doc 2019 01 29 51 54 ...
Page 52: ...PRTxxMF series readers Operating Manual doc 2019 01 29 52 54 ...
Page 53: ...PRTxxMF series readers Operating Manual doc 2019 01 29 53 54 ...