PRTxxMF series readers Operating Manual.doc
2019-01-29
38/54
The reader searches its memory for the presented card. Once successful it removes it from the
memory and the record previously occupied by this card is released. This command removes only
card, if the user has PIN then it still can be used.
[23][ID] – Delete a user with given ID
A user with entered ID is deleted (both his card and his PIN are removed), a new user can be
programmed to use this ID index.
[24][YYMMDDhhmm] – Setting date and time
Where: YY – two last digits of year (00-99), MM – month (01-12), DD – day (01-31), hh – hour
(00-23), mm – minute (00-59)
[#] – Exit from User Programming Mode
After exiting from the User Programming mode reader returns to either armed or disarmed mode
depending on which one was set prior to User Programming Mode.
Programming Examples
Example 1: Add a new TOGGLE LTD user with a card; programming sequence: [1][8][Card][#] or
[1][8][Card][Wait ~10s or press [#]]
Read your MASTER card or enter MASTER PIN
The reader enters User Programming mode (LED OPEN is on and LED STATUS
is
on and red)
Press [1][8]
LED SYSTEM starts flashing
Present a card which you want assign for a new TOGGLE LTD user
Press [#], command is completed
The reader has completed programming function, however, it has not left User Programming mode
so now you can enter another programming command.
Example 2: Delete a user with ID=45; programming sequence: [2][3][0][4][5]
Read your MASTER card or enter MASTER PIN if you are not in User Programming mode
The reader enters User Programming mode (LED OPEN is on and its LED STATUS
is on and red)
Press [2][3]
LED SYSTEM starts flashing
Press [0]
Press [4]
Press [5]
Press [#], command is completed
The user with ID=45 has been deleted, reader still remains in User Programming mode, so now
you can enter another programming command.
1 0 .
P
R O G R A M M I N G
F
R O M
P C
The reder can be fully programmed from the PC through standard COM port (RS232) or via
dedicated RUD-1 interface (USB port). In both cases the RARC program is required. In order to
establish the connection, select
Options->Port
command in RARC software, then
Connection-
>Connect…,
the option
RS232
and then the button
Start.
10.1.
P
ROGRAMMING VIA
RS232
COM
PORT
In this scenario connection between programmed reader and PC requires four wires: GND, RXD,
TXD and RTS as presented on the drawing below. The reader must be supplied from the external
source of power.
Summary of Contents for PRT MF Series
Page 47: ...PRTxxMF series readers Operating Manual doc 2019 01 29 47 54 ...
Page 48: ...PRTxxMF series readers Operating Manual doc 2019 01 29 48 54 ...
Page 49: ...PRTxxMF series readers Operating Manual doc 2019 01 29 49 54 ...
Page 50: ...PRTxxMF series readers Operating Manual doc 2019 01 29 50 54 ...
Page 51: ...PRTxxMF series readers Operating Manual doc 2019 01 29 51 54 ...
Page 52: ...PRTxxMF series readers Operating Manual doc 2019 01 29 52 54 ...
Page 53: ...PRTxxMF series readers Operating Manual doc 2019 01 29 53 54 ...