25
4. Turn the select knob to display the menu to be adjusted.
5. Rotate the Alpha dial to change the setting.
6. Turn the Select knob to move to the next menu, if desired and Repeat step 5.
Note: An Audio Save may be performed to save these settings as the default. See Audio Save on
page 23.
Antiphonal On/Main Off
The T807 is prepared with ANTIPHONAL ON (ANT ON)/MAIN OFF lighted pistons that can
operate an additional speaker system. An antiphonal speaker system is usually installed at the
opposite end of the building from the main organ allowing greater musical flexibility. The
ANTIPHONAL ON piston activates this additional speaker system, and the MAIN OFF piston
turns off the main organ.
Note: If the MAIN OFF piston is engaged, the ANTIPHONAL ON piston must be engaged or the
organ will not sound through either system (it is possible for the installer to change the function
of these pistons).
Zimbelstern
The Rodgers T807 is prepared for a Zimbelstern (bell star). This percussive device is most often
used in bright music of the Baroque period. The Zimbelstern (ZIMBEL) is activated by a lighted
reversible piston located under the Swell manual to the right.
Pipes
Any digital sampled rank in the Rodgers T807 may be replaced by a real wind-blown pipe rank.
If a limited range of pipes is available, sampled voices from the Rodgers T807 can fill out the
entire range. Preparations for controlling real expression shutters are already included in the
organ software.
Note: See
Shutter Thickness
on page 20.
Contact your authorized Rodgers representative for additional information.
Pipes Off/Ancillary On
If the Rodgers T807 is equipped with pipe ranks, certain stops control pipe voices (with any
electronic extensions set up during installation and voicing) and other stops control digitally
sampled voices. There are two pistons affecting the pipe stops of all divisions simultaneously
(ANC ON and PIPES OFF).
When the ANC ON piston is engaged, digital voices play from the pipe stops. When the PIPES
OFF piston is engaged, the real wind blown pipes turn off.
Note: If the PIPES OFF piston is engaged, the ANC ON piston must also be engaged for the
stop(s) to sound.