PowerFlex Digital DC Drive User Manual -
Publication 20P-UM001C-EN-P - July 2008
Programming and Parameters
3-11
Monitor File
File
Gr
oup
No.
Parameter Name & Description
for symbol descriptions
Values
Re
lat
ed
MO
NIT
O
R
Speed Meters
44
[Speed Ref A]
First speed reference for the drive. Negative values apply to four
quadrant drives only.
Note: This parameter is assigned to analog input 1 (terminals 1
& 2, Par 70 [Anlg In1 Sel]) by default, but can be assigned to any
analog input.
Default:
Min/Max:
Units:
Read Only
–/+ Par 45 [Max Ref Speed]
(1)
RPM
45
(1)
The value of [Max Ref Speed] cannot exceed 8192 RPM.
47
[Speed Ref A Pct]
First speed reference for the drive as a percentage of the value
defined in Par 45 [Max Ref Speed].
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
45
48
[Speed Ref B]
Second speed reference for the drive. Negative values apply to
four quadrant drives only.
Note: This parameter can be assigned to an analog input.
Default:
Min/Max:
Units:
Read Only
–/+ Par 45 [Max Ref Speed]
(1)
RPM
45
(1)
The value of [Max Ref Speed] cannot exceed 8192 RPM.
49
[Speed Ref B Pct]
The second speed reference for the drive as a percentage of the
value defined in Par 45 [Max Ref Speed].
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
45
110
[Ramp In]
Total reference value input to the ramp in RPM.
Note: This parameter can be assigned to an analog output.
Default:
Min/Max:
Units:
Read Only
–/+32766
RPM
111
[Ramp In Pct]
Total reference value input to the ramp as a percentage of Par
45 [Max Ref Speed].
Note: This parameter can be assigned to an analog output.
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
45
113
[Ramp Out]
Output of the ramp in RPM.
Note: This parameter can be assigned to an analog output.
Default:
Min/Max:
Units:
Read Only
–/+32766
RPM
114
[Ramp Out Pct]
Output of the ramp as a percentage of Par 45 [Max Ref Speed].
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
45
117
[Speed Reg In Pct]
Total reference value input to the Speed Regulator as a
percentage of Par 45 [Max Ref Speed].
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
118
[Speed Reg In]
Total reference value input to the Speed Regulator in RPM.
Note: This parameter can be assigned to an analog output.
Default:
Min/Max:
Units:
Read Only
–/+32766
RPM
121
[Spd Feedback Pct]
Actual speed as a percentage of the Par 45 [Max Ref Speed].
Note: This parameter is assigned to analog output 1 (terminals
21 and 22, Par 66 [Anlg Out1 Sel]) by default, but can be
assigned to any analog output.
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
45,
923
122
[Spd Feedback]
Actual speed in RPM.
Default:
Min/Max:
Units:
Read Only
–/+32766
RPM
384
[Spd Ref Out Pct]
Output of the Speed Reference selection as a percentage of Par
45 [Max Ref Speed].
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
45
385
[Speed Ref Out]
Output of the Speed Reference selection.
Default:
Min/Max:
Units:
Read Only
–/+32766
RPM
420
[Encoder Speed]
Actual speed measured by the digital encoder.
Default:
Min/Max:
Units:
Read Only
–/+8192
RPM
414