2-48 Parameter
Descriptions
7000-TD002A-EN-P – September 2007
Autotune Isd Step
[Autotune Isd Stp]
Linear Number:
216
Default Value:
0.100 pu
Minimum Value:
0.010 pu
Maximum Value: 0.200 pu
Access Level:
Advanced
Read/Write:
Read/Write
This parameter specifies the size of the step that is added to the magnetizing current command during
auto-tuning of the flux regulator for synchronous machines. It is not used for induction motors.
Contact factory for availability
Autotune Speed Command [Autotune Spd Cmd]
Linear Number:
213
Default Value:
30.0 Hz
Minimum Value:
20.0 Hz
Maximum Value: 60.0 Hz
Access Level:
Advanced
Read/Write:
Read/Write
This parameter specifies the speed command used during auto-tuning of the flux regulator and total
inertia. The overall drive Speed Command Minimum and Maximums are still active during auto-tuning.
Autotune Torque Step [Autotune Trq Stp]
Linear Number:
215
Default Value:
0.100 pu
Minimum Value:
0.050 pu
Maximum Value: 0.500 pu
Access Level:
Advanced
Read/Write:
Read/Write
This parameter specifies the size of the torque step that is added to the torque command during auto-
tuning of the total inertia. A value of 1.000 corresponds to rated torque. The overall Torque Command
Limits are still active during auto-tuning.
Summary of Contents for PowerFlex 7000
Page 1: ...PowerFlex 7000 Medium Voltage AC Drive TECHNICAL DATA Firmware Version 7 xxx ...
Page 2: ......
Page 4: ...ii Table of Contents 7000 TD002A EN P September 2007 ...
Page 44: ...1 40 Functional Description 7000 TD002A EN P September 2007 ...
Page 244: ......
Page 346: ...3 58 Troubleshooting 7000 TD002A EN P September 2007 ...
Page 349: ......