Troubleshooting
3-33
7000-TD002A-EN-P – September 2007
WARNING MESSAGES
WARNING
MESSAGE
WARNING
CODE
DESCRIPTION
RECOMMENDED ACTIONS
AC/DC#1 AC Fail
108
AC/DC#2 AC Fail
109
AC/DC#3 AC Fail
110
AC/DC#4 AC Fail
111
There has been a loss or dip in the control
power feeding the drive. Ensure that the
power source is active and investigate the
reliability of the source.
–
Investigate possibility of loss of input
voltage to the AC/DC Power Supply
–
Verify output voltage
–
Check alarm signal connections
–
Replace Power Supply if necessary
AC/DC#1Redundant
104
AC/DC#2Redundant
105
AC/DC#3Redundant
106
AC/DC#4Redundant
107
Redundant AC/DC Power Supply#1-4 has
failed. Verify electrical connections.
–
Replace PS if necessary.
Adapter 1 Loss
49
Adapter 2 Loss
50
Adapter 3 Loss
51
Adapter 4 Loss
52
Adapter 5 Loss
53
Adapter 6 Loss
54
There has been a loss of communication
between the DPM and the Adapter 1-6.
Ensure that the Adapter is plugged in the
ACB, powered and working properly. Cycle
power to the drive if necessary.
–
Ensure that the remote communication
device is powered
–
Verify the light status and ensure the
communication device is operating
properly
–
Verify the customer network is properly
communicated with the device
–
Check LED status
–
Cycle control power to the drive
–
Change the adapter if all attempts to
restore communication fail
AIn1 Calib Error
224
AIn2 Calib Error
225
AIn3 Calib Error
226
The analog input supplied was outside of
the allowable range of 4-20 mA during
calibration. Recalibrate with the proper
range.
–
Verify the calibration of Analog inputs
Ambient FbrOptic
221
The drive has detected a missing
temperature sensor to the Temperature
Feedback Board (TFB). Ensure that the
sensor in plugged in
–
NOT USED
Ambient OvrTemp
217
Drive detected high ambienttemperature.
–
NOT USED
Ambient Sensor
219
The drive has detected a missing
temperature sensor to the Temperature
Feedback Board (TFB). Ensure that the
sensor in plugged in
–
NOT USED
Autotune TimeLmt
62
Autotune test failed to complete in 2
minutes. Perform test manually.
–
REFER TO THE POWERFLEX 7000
DRIVE USER MANUAL (CHAPTER –
COMMISSIONING) ON AUTOTUNE
PROCEDURES, RESULTS, AND
ACTIONS
Auxiliary Prot’n
79
Standard External Fault/Warning Input
included to allow the end-user to install a
protective relay/system status contact that
can activate a drive fault or warning,
depending on configuration of Aux Prot
Class (P445)
–
See associated Fault Description
–
The drive has detected an alarm
triggered by the input wired in the
auxillary input of the XIO card. The
alarm is user configurable by
parameters in Alarm Config. Investigate
the cause of the alarm. Check the 120V
wiring and the XIO card.
Summary of Contents for PowerFlex 7000
Page 1: ...PowerFlex 7000 Medium Voltage AC Drive TECHNICAL DATA Firmware Version 7 xxx ...
Page 2: ......
Page 4: ...ii Table of Contents 7000 TD002A EN P September 2007 ...
Page 44: ...1 40 Functional Description 7000 TD002A EN P September 2007 ...
Page 244: ......
Page 346: ...3 58 Troubleshooting 7000 TD002A EN P September 2007 ...
Page 349: ......