Rockwell Automation Publication 6181P-UM003A-EN-P - May 2014
31
Installation
Chapter 2
8.
Hand-tighten the mounting clips around the bezel by following the
tightening sequence below.
9.
Repeat this process at least three times until the clips are hand-tight and
the gasket is compressed uniformly against the panel.
10.
Tighten the mounting clips to a torque of 1.35 N•m (12 lb•in) by
following the torquing sequence on the previous page, making sure to not
overtighten.
11.
Repeat this process at least three times until the clips are properly torqued,
making sure the gasket is compressed uniformly against the panel.
ATTENTION:
Tighten the mounting clips to the specified torque to
provide a proper seal and prevent damage to the product. Rockwell
Automation assumes no responsibility for water or chemical damage to
the computer or other equipment within the enclosure because of
improper installation.
All Standard (4:3 and 5:4) Display Models with
Aluminum Bezel except 1900P Display
1500P Standard Display with
Stainless Steel Bezel
5
4
3
6
9
1
10
8
2
7
1700P Standard Display with Stainless Steel Bezel
5
4
3
6
11
12
9
1
10
8
2
7
1500P Widescreen (16:9) Display
All 1900P Standard and Widescreen Display Models
8
3
4
7
10
1
5
11
6
2
13
8
7
14
3
4
10
1
5
11
6
2
9
12
12
9