Qualified personnel
Qualified personnel must be able to correctly interpret and implement the safety instructions
and warnings. They must also be familiar with the safety concepts of automation technology
and have received appropriate training. Non-qualified interventions in the devices or failure
to observe the warning notices in this documentation or the warning notices displayed by the
device may result in damage to property or personal injury.
EU directives on product safety
The following EU directives have been observed:
2011/65EU
RoHS
2014/30/EU
Electromagnetic compatibility (EMC)
DIN EN 61010-1 Safety requirements for electrical equipment for measurement, control,
and laboratory use - Part 1: General requirements
DIN EN 61326-1 Electrical equipment for measurement, control, and laboratory use - EMC
requirements
Other applicable regulations
In addition to this technical manual, the following regulations must be observed:
•
Accident prevention regulations
•
Local occupational safety regulations
Safety regulations
●
The ELS should only be used by authorised specialist personnel and in compliance with
accident prevention regulations and the regulations of the electrical industry.
●
Unqualified persons must not put the control unit into operation.
●
The control unit is designed for operating temperatures of +5 to +40 °C and storage
temperatures of -10 to +50 °C. The control unit must not be operated by unqualified persons.
It must be protected from high humidity, vibrations and explosive gases.
●
Before opening the device, it must be disconnected from the power supply.
●
Connection and installation work may only be carried out when the device is de-energized.
Assembly and use of equipment must be carried out in accordance with the standards of
the Declaration of Conformity.
●
When connecting motors to motor drivers, the correct polarity must be observed.
Furthermore, the correct motor current must always be set on the driver. In order for the
speed of the motor to be correctly controlled, the steps/revolution must also be set on the
driver. This setting must also be adopted in the settings of the ELS.
●
The respective configuration of the controller may only be operated with the motor types
configured for it. Other or further uses do not correspond to the intended purpose.
●
Currents and voltages: The ELS works with a low voltage of 12V, which can be provided by a
power supply unit. Therefore, no special safety precautions are required on the output side.
The ELS is built in accordance with the recognised safety regulations and complies with the
8