Quick Start for Dynamixel Pro v1.00b
Page
21
/
139
vi.
Accelerating Dynamixel PRO in Joint Mode
-
Verify if Dynamixel PRO is set as torque off status. If not, click on the Torque
Enable (#562) on Control Table and set the value to 0. Click the ‘Apply’ to change
it to torque off status.
-
Modify the Operating Mode (#11) value as 3 then click ‘Apply’ to set Dynamixel
PRO as Joint Mode.
-
Set Goal Acceleration (#606) value as 4, then click ‘Apply.’
-
Set Torque Enable (#562) value as 1 and click ‘Apply’ to change Dynamixel PRO
to ‘Torque On’ status.
-
Set the Goal Position (#596) value to 100,000 or -100,000, then click ‘Apply.’
Note the difference in the movement of Dynamixel PRO from the time the Goal
Acceleration was set to 0.
Summary of Contents for Dynamixel Pro
Page 1: ...Quick Start for Dynamixel Pro ...
Page 8: ...Quick Start for Dynamixel Pro v1 00b Page 8 139 ...
Page 33: ...Quick Start for Dynamixel Pro v1 00b Page 33 139 Check Dynamixel PRO firmware update results ...
Page 37: ...Quick Start for Dynamixel Pro v1 00b Page 37 139 Dynamixel PRO firmware recovery is complete ...
Page 66: ...Quick Start for Dynamixel Pro v1 00b Page 66 139 The present temperature is constantly read ...
Page 133: ...Quick Start for Dynamixel Pro v1 00b Page 133 139 2 3 2 42 series H42 L42 ...
Page 136: ...Quick Start for Dynamixel Pro v1 00b Page 136 139 ...
Page 138: ...Quick Start for Dynamixel Pro v1 00b Page 138 139 iii L42 10 S300 R ...
Page 139: ...Quick Start for Dynamixel Pro v1 00b Page 139 139 2 5 Model notation ...