ORBIT 16
E10 PROTECTION COVER OPEN ALARM
Cause:
-
Protection cover open
Remedy:
-
Close the cover and press the Reset button
Cause:
-
Limit switch malfunction
Remedy:
-
replace power switch
E20 THERMAL PROTECTION ALARM
Cause:
-
Thermal or magneto - thermal relay protection
Remedy:
-
Eliminate the overload cause, reset guards with the specific reset. Press the "Reset"
button
E30 FAULT INVERTER OVERLOAD
Cause:
-
Inverter in error
Remedy:
-
Check the alarm on the inverter display and refer to the technical manual
E40 ROTATING RING IMPROPERLY TIMED WITH THE SEALING
Cause:
-
Rotating ring and sealing improperly timed
Remedy:
-
If the units are in homing position, check the sensors; otherwise, move them to “Home”
position manually
E42 ROTATING RING IMPROPERLY TIMED
Cause:
-
Rotating ring improperly timed
Remedy:
-
Check the rotation Home sensor
E60 PRODUCT INFEED PHOTOCELL ALARM
Cause:
-
The photocell detects that the product is not in the correct position or that the reflector is
not properly aligned
Remedy:
-
Remove the product or align the photocell with the reflector
E61 PRODUCT OUTFEED PHOTOCELL ALARM
Cause:
-
The photocell detects that the product is not in the correct position or that the reflector is
not properly aligned
Remedy:
-
Remove the product or align the photocell with the reflector
E62 “GRIPPER NOT IN POSITION” ALARM
Cause:
-
Clamp cylinder magnetic sensors not properly working
Remedy:
-
Check and replace the sensor if necessary
E64 "FILM RUPTURE" ALARM
Cause:
-
The film has broken or reel is empty
Remedy:
-
Insert the film or replace reel
88/95