![ROBO Cylinder RCP6SW Instruction Manual Download Page 50](http://html.mh-extra.com/html/robo-cylinder/rcp6sw/rcp6sw_instruction-manual_1470818050.webp)
42
1.
S
pecification
s Che
ck
[When high-output setting for side-mounted motor type is effective]
In RA8R there is nothing related to high-thrust setting. There is no parameter setting.
When the ambient operating temperature is 5°C to 40°C
Type
Motor
Type
Lead
[mm]
Horizontal/
Vertical
Transportable Mass by
Acceleration/Deceleration [kg]
Velocity
[mm/s]
0.1G
0.2G
RA8R
60P
5
Horizontal
0
100
-
80
100
-
90
100
-
100
75
-
Vertical
0
70
-
45
70
-
60
45
-
70
35
-
80
25
-
90
14
-
100
9
-
10
Horizontal
0
-
60
160
-
60
170
-
40
180
-
25
190
-
15
200
-
12
Vertical
0
-
35
80
-
35
90
-
34
100
-
28
110
-
23
120
-
18
130
-
15
140
-
12
150
-
10
160
-
8
170
-
6
180
-
4
190
-
3
200
-
2
20
Horizontal
0
-
30
300
-
30
350
-
14
Vertical
0
-
3
300
-
3
330
-
1