45
No.
7.5 How to Set the Home Preset and Home Return Offset
Correct any position deviation by changing the home preset parameter when an ASEL controller is used, or home
return offset parameter when an ACON controller is used. How to set each parameter is explained below.
7.5.1 ASEL Controller
(1) Open the position edit screen.
Click
on the the PC software screen, choose
Select Position Number
, and then click
OK
. The
following screen appears.
(2) Compare the value of the current position against that of the position number corresponding to the desired
position to which the actuator has been moved, and check the deviation.
The current position is shown.
Position number
MV
Click the [MV] button.
Select the position to move
the actuator to.
Click this button and make selection on the displayed position.