38
5.7
Cleanroom Specification
5.7.1 Suction Rate
Air inside the actuator must be suctioned to ensure that the actuator operates in conformance with the
requirements of cleanliness class 10.
Provide an air tube and connect it to a quick joint (outer diameter
6) provided at the suction section, and
connect the other end of the tube to a vacuum pump, blower, ejector, etc., to suction at an applicable flow rate as
specified below.
Lead
Recommended suction rate
2.5 mm/3 mm
15 NI/min
5 mm/6 mm
30 NI/min
10 mm/12 mm
50 NI/min
20 mm
80 NI/min
5.7.2 Suction Joint
Remove the plug from either quick joint and insert an air tube to suction air from either the motor side or
counter-motor side.
Remember to cover the unused joint with a plug.
Plug
Quick joint
Quick joint
Air tube of outer diameter
6 (provided by the customer)