SECTION 1: H
EATER
S
AFETY
3
FIGURE 2: Side and Back Panel Label Placement
FIGURE 3: Serial Number Identification Chart
Clearances to Combustibles Label
Control Side Panel
Control Side Panel (Inside)
Wiring Label
Level
droit
Level
droit
CTH2V/HEV-40
CTH2V/HEV-60
CTH2V/HEV-80
CTH2V/HEV-100
CTH2V/HEV-125
CTH2V/HEV-150
CTH2V/HEV-175
CTH2V/HEV-40
CTH2V/HEV-60
CTH2V/HEV-80
CTH2V/HEV-100
CTH2V/HEV-125
CTH2V/HEV-150
CTH2V/HEV-175
CTH2V/HEV-40
CTH2V/HEV-60
CTH2V/HEV-80
CTH2V/HEV-100
CTH2V/HEV-125
CTH2V/HEV-150
CTH2V/HEV-175
P/N 91013436 Orig.
Level
droit
Level
droit
CTH2V/HEV-40
CTH2V/HEV-60
CTH2V/HEV-80
CTH2V/HEV-100
CTH2V/HEV-125
CTH2V/HEV-150
CTH2V/HEV-175
CTH2V/HEV-40
CTH2V/HEV-60
CTH2V/HEV-80
CTH2V/HEV-100
CTH2V/HEV-125
CTH2V/HEV-150
CTH2V/HEV-175
CTH2V/HEV-40
CTH2V/HEV-60
CTH2V/HEV-80
CTH2V/HEV-100
CTH2V/HEV-125
CTH2V/HEV-150
CTH2V/HEV-175
P/N 91013436 Orig.
P/N 91030310 Rev A
POWER SUPPLY
120V 60 HZ
L1
L2
GAS
VALVE
GRN
BLK
WHT
MOTOR/BLOWER
GRN
BLK
BLK
BLK
BUSHING
TERMINAL
3
1
4
5
TRANSFORMER
GRN
IGNITION
MODULE
YEL
BRN
BLUE
YEL
PURPLE
YEL
WHT
PRESSURE SWITCH
PLUG
3
1
R1
R1
YEL
24V STAT
BY OTHERS
BLUE
BUSHING
TERMINAL
LED
+
ELECTRODE
DOOR
SWITCH
YEL
C R W
NOTES:
NO TERMINAL BUSHING
ON HARSH ENVIRONMENTS,
THERMOSTAT CONNECTIONS
MADE INTERNAL
SEE NOTE 1
TH
C1
V1
C2
S1
V2
GND
BLK
N.O.
COM
P/N 91030310 Rev A
POWER SUPPLY
120V 60 HZ
L1
L2
GAS
VALVE
GRN
BLK
WHT
MOTOR/BLOWER
GRN
BLK
BLK
BLK
BUSHING
TERMINAL
3
1
4
5
TRANSFORMER
GRN
IGNITION
MODULE
YEL
BRN
BLUE
YEL
PURPLE
YEL
WHT
PRESSURE SWITCH
PLUG
3
1
R1
R1
YEL
24V STAT
BY OTHERS
BLUE
BUSHING
TERMINAL
LED
+
ELECTRODE
DOOR
SWITCH
YEL
C R W
NOTES:
NO TERMINAL BUSHING
ON HARSH ENVIRONMENTS,
THERMOSTAT CONNECTIONS
MADE INTERNAL
SEE NOTE 1
TH
C1
V1
C2
S1
V2
GND
BLK
N.O.
COM
Lighting Instruction Plate Label
Vent Length Label
Back Panel
Description
Part Number
Lighting Instruction Plate Label
91029602
Wiring Label
91030310
Clearances to Combustibles Label
91013436
Vent Length Label
91039500
2103-038-150-0456
Manufactured
Year
Manufactured
Month
Numerical
Model Number
Burner Maximum
Firing Rate (MBH)
Numerical sequence
of units manufactured for
the month of the given product
Serial numbers are located on both the burner shipping carton and the data plate. Each burner will have a unique 14-digit serial
number used for identification purposes to allow the lookup of various items such as manufacture test records, replacement part
identification, and manufactured date.
Summary of Contents for VANTAGE HEV-100
Page 2: ......
Page 4: ......
Page 25: ...SECTION 6 HEATER INSTALLATION 21 FIGURE 20 Linear Heater Layout Overview Continued ...
Page 41: ...SECTION 7 OPTIONAL HEATER ACCESSORIES 37 FIGURE 30 U Tube Heater Layout Overview Continued ...
Page 72: ...HEV SERIES INSTALLATION OPERATION AND SERVICE MANUAL 68 ...
Page 73: ...SECTION12 TROUBLESHOOTING 69 12 2 Manifold Gas Pressure Setting Side View of Heater ...
Page 78: ......
Page 79: ...2020 ...
Page 80: ......