SECTION 10: W
IRING
61
10.5 Ladder Diagram
10.6 Electrical Connection to the Burner Box using Line Voltage Thermostat on Control
120VAC
R1
120VAC
24VAC
RELAY
24V
PRESSURE
TH
V2
S1
SPARK
C2
TRANSFORMER
(L1)
GND
(L2)
SWITCH
THERMOSTAT
BLOWER
LINE
NUETRAL
R1
ELECTRODE
GAP
V
BURNER ON
GAS VALVE
DOOR
SWITCH
R
C
W
Green
White
Black
L1
L2
Gnd.
Conduit Hole
Burner Box
Internal Wire Bundle
Connect wires together with
suitable approved wire connections.
Green to Gnd.
White to L2
Black to L1
Liquid Tight Flexible
Conduit for Outdoor
Use or Equivilent
Liquid Tight Conduit
Connector