TECHNICAL FILE
1200W HMI FOLLOW SPOT
REFLECTOR.
- Disconnect from the mains.
- Open the bonnet and the side covers of the lantern.
- Take out the lamp.
( Refer to the page 14 ).
- Unscrew the 2 screws 1 .
- Withdraw the reflector holder set 2 .
- Clean the reflector 3 with a soft dry cloth.
ASPHERIC LENS.
- Unscrew the 2 screws 4 .
- Withdraw the lens holder set 5 .
- Clean the lens 6 with a soft dry cloth.
- Remount all the parts.
- Clean in the same way, the lenses in the zoom.
SPARK-GAP.
- Disconnect from the mains.
- Open the lantern's bonnet.
- Unscrew the nut a , while holding in place the counter-nut b
.
- Then, unscrew the counter-nut b .
- Adjust, with a 2,5 Allen key, the upper electrode c to
1 mm from the electrode.
- Tighten the counter-nut b and the nut a .
• The adjustment is made, when manufactured.
Interfere only in case of a faulty starting.
1 mm
a
b
c
8
8
2,5
1
4
6
2
5
3
1
4
Disconnect from the mains before any servicing.
Service only by qualified technician.
1011+, 1011+B &
1011+C
Summary of Contents for 1011+