TECHNICAL FILE
1200W HMI FOLLOW SPOT
1011+B
3.3. The off command is given, but the lamp
stays on.
message unchanged.
4 . NON-FUNCTIONING DIAGNOSIS FOR THE SHUTTER :
1.1 The shutter command is given, but no
action.
1.2 . The shutter only excepts an up command,
does not except an down command.
resend the
level
command.
New shutter level
displayed.
Shutter cable demaged :
Check cable.
Faulty power supply :
Change CAD :
( Refer to Tech. File - page 40 )
The shutter does
not react or reacts
badly.
Motor demaged : Change the
whole shutter unit.
( refer to Tech. File - page 32 )
1.3 . The shutter reacts badly, and the motor
runs continuous.
1.4. The shutter act in a saw-tooth movement
on a fluent command.
1.5. Shutter action is delayed to command.
The shutter level is
correctly displayed.
Error on the Shutter unit :
Change the whole shutter unit.
( refer to Tech. File - page 32 )
Green &
red LED :
off
Transmission Data error :
connection failure : check the wiring.
( refer to Tech. File p. 12 & 24 ).
connection damaged or :
( refer to Tech. File p. 12 & 24 ).
message unchanged.
Resend the
"LAMP OFF"
command.
New shutter level
not displayed.
Command link error :
Digital - refer to 3.1.
Analog - refer to 2.
Green &
red LED
on.
Resend the
"LAMP OFF"
command.
resend the
level
command.
resend the
level
command.
resend the
level
command.
resend the
level
command.
Summary of Contents for 1011+