robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat r
eserve the right to change or alter any of the items detailed on this page, to incr
ease or impr
ove manufacturing
techniques without prior notice.
VALID SINCE
: 16.02.05
DocT
ech1011_BC_0205.ind
10
TECHNICAL FILE
1200W HMI FOLLOW SPOT
Power supply unit
(P.S.U.)
CONNECTIONS.
1011+ & 1011+C
Mains voltage.
- Check the conformity of the power supply unit.
Rating plate 11 : Lamp power.
Lighting unit / Power supply connection.
- Connect the Lighting unit/Power supply cable C by passing it
inside the yoke.
- Leave a little slack and then block the cable C into the lock d .
- Place the lamp into position - refer to page 14.
- Connect the cable 2 to the mains.
CAUTION - For your security !
- Never open the lantern's bonnet when the
lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when lamp in place.
DESCRIPTION.
A 1011
+
Manual shutter version.
e - EM HARTING 16 x 16A power socket.
f - 10A. EEC - Female mains socket.
B
Power supply unit.
1
- EF HARTING 16 x 16A - 2 latch connector.
2
- Mains cable.
3
- Time meter.
4
- General 16A circuit breaker (
208/245V
).
- General 25A circuit breaker (
110V
).
5
- Mains, checklight.
6
- 1A automatic breaker.
7
- "ON/OFF" switch.
8
- "Wieland" 2 point connector : remote control.
9
- Lamp ON, checklight.
If the lamp's checklight is OFF when the switch is in
the ON position; the lighting of the lamp has failed.
Repeat the operation - refer to page 14.
10 & 11
- Rating plate.
C Lamp
cable.
Cable H07 RN-F 19G 1,5mm
2
length 3m fitted
with 16 x 16A M/F HARTING connectors.
d
0 - OFF
0 - OFF
30.23
LAMP ON
ON
TELECOMMANDE /
REMOTE CONTROL
AMONT
MAINS
FUSE
OFF
3
8
9
1
10
11
7
5
6
4
2
B
HMI 1200
220/240V 50Hz
0 - OFF
Summary of Contents for 1011+