robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat r
eserve the right to change or alter any of the items detailed on this page, to incr
ease or impr
ove manufacturing
techniques without prior notice.
VALID SINCE
: 16.02.05
DocT
ech1011_BC_0205.ind
24
TECHNICAL FILE
1200W HMI FOLLOW SPOT
CONNECTION.
1011+B
a
b & g
C A D 900
C A D 900
a b c d
f
1 Fan phase.
2 Ballast phase.
3 Lamp Neutral.
4
5
6 Security return 1200.
7 Security return 2500.
8 Security not used.
9 Ignition timed phase.
10 Ballast phase.
11 Lamp Neutral.
12 Earth.
13 Aux. phase.
14 Aux. Neutral.
15 Common security.
16 Earth.
Female side earth only.
Cable CAD 900/Mechanical Shutter.
7
Lamp cable.
Ballast side.
FMD 16 x16 A
HARTING.
e
Lighting unit side.
FFD 16 x16 A
HARTING.
Cable H07 RN-F
19 G 1,5.
CAD 900 side.
FM XLR 7.
Shutter side.
FF XLR 7.
Flexible cable
14 x 0,14 shielded
CN14.
REP
DESIGNATION
DESIGNATION
REP
1 0V. GND.
2 Lamp circuit. IN
3 Shutter circuit. IN
4 +15V. OUT
DESIGNATION
REP
d
Flexible cable
5 x 0,14 shielded.
0/+10V control cable
1 0V.
2 DATA - IN.
3 DATA + IN.
4
5
DESIGNATION
REP
1 0V.
2 DATA - OUT.
3 DATA + OUT.
4
5
DESIGNATION
REP
Flexible cable
5 x 0,14 shielded
CN5.
FF XLR 5.
FM XLR 5.
Flexible cable
5 x 0,14 shielded
CN5.
DATA Link.
Delivered standard : 3m.
Delivered standard : 3m.
0V.
DATA -
DATA +
PWM
INFO 0/+10V
+U
- U
/
DESIGNATION
REP
1 0V.
2 DATA -
3 DATA +
4 PWM
5 INFO 0/+10V
6 +U
7 - U
NC /
DESIGNATION
REP
4 x 0,14
1 x 0,14
1 x 0,14
1 x 0,14
1 x 0,14
3 x 0,14
3 x 0,14
Shielded
1
2
3
4
5
6
7
SHELL
c
Delivered standard : 3m.
Ballast side.
FF XLR 4
250V. 10A. EEC male mains connector
for power feed for the fan.
k
L Phase
N Neutral
Earth
DESIGNATION
REP
Note:
This is a universal cable and is suitable for a follow spotlight
or a profile, 1200W. or 2500W.
c
Summary of Contents for 1011+
Page 2: ...NOTES ...