background image

1

Summary of Contents for scan 1200 XT

Page 1: ...1 ...

Page 2: ...2 ...

Page 3: ... PROTOCOL 10 6 Controller mode 13 6 1DMX addressing 13 6 2 Remotely controllable functions 13 7 Stand alone mode 15 8 Functions of the control panel 16 8 1 Addressing 16 8 2 Slave control 17 8 3 Fixture informations 17 8 4 Personality options 19 8 5 Switching On Off the lamp 23 8 6 Test sequences 23 8 7 Stand alone setting 23 8 8 Reset function 25 8 9 Special functions 25 9 Error and information m...

Page 4: ...other cables Handle the power cord and all connections with the mains with particular caution Always plug in the power plug least The power plug has to be accessable after installing the device Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time Always disconnect from the mains when the device is not in use or before cleani...

Page 5: ...d that the housing is firmly closed and all screws are tightly fastened The lamp must never be ignited if the objective lens or any housing cover is open as discharge lamps may explose and emit a high ultraviolet radiation which may cause burns The maximum ambient temperature ta 45 C must never be exceeded Otherwise the lamp is switched off and the fixture is out of operation for 5 minutes CAUTION...

Page 6: ...2 Bracket 3 Fixation screw for bracket 4 Objective 5 Mirror Front panel 6 DMX Input 7 DMX Output 8 Powercord 9 Fuseholder 10 Control board 11 Voltage frequency selection panel Control board 12 Enter button 13 Display 14 Mode button 15 Up Down buttons ...

Page 7: ... the housing and tighten the fastening screws Before striking the lamp reset the LAti and LASt counters in the INFO menu of the control board by pressing the Up and Down buttons at the same time and then confirming with the Enter button Do not operate this fixture with opened housing cover 4 2 Inserting Exchanging rotating gobos DANGER Install the gobos with the device switched off only Unplug fro...

Page 8: ...power Connect the scanner to the mains with the enclosed power plug If you need to install other power plug on the power cable follow the identification table below The earth has to be connected The occupation of the connection cables is as follows Cable EU Cable US Pin International Brown Black Live L Light blue White Neutral N Yellow Green Green Earth Do not connect the scanner to a dimmer syste...

Page 9: ... in the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 W resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture Building a master slave chain Connect the DMX ...

Page 10: ...29 No function step 230 239 Lamp off after 3 sec step 240 255 No function step 7 7 5 Colour 1 0 Open white proportional 14 Red proportional 28 Blue proportional 43 Green proportional 57 Yellow proportional 71 Magenta proportional 85 Light blue proportional 100 Turquoise proportional 114 Orange proportional 127 White proportional 128 190 Forwards rainbow effect from fast to slow proportional 190 19...

Page 11: ...1 step 64 95 Gobo 2 step 96 127 Gobo 3 step 128 159 Gobo 4 step 160 191 Gobo 5 step 192 255 Gobo wheel rotation fro slow to fast proportional 11 11 9 Rotating gobo 0 63 Open step 64 95 Rot gobo 1 metal step 96 127 Rot gobo 2 metal step 128 159 Rot gobo 3 dichroic step 160 191 Rot gobo 4 glass step 192 255 No function step 12 12 10 Rotating gobo index rotating gobo rotation 0 127 Gobo indexing prop...

Page 12: ...shutter open step 128 159 Pulse effect in sequences proportional 160 191 No function shutter open step 192 223 Random strobe effect from slow to fast proportional 224 255 No function shutter open step 16 16 14 Dimmer intensity 0 255 Gradual adjustment of the dimmer intensity proportional from 0 to 100 Mode 1 Mode 2 8 bit Value Function Type of control channel channel channel ...

Page 13: ...lay inside of the SCAN 1200 XT allows you to switch on and off the lamp via the control panel on the front panel or via your controller without affecting the rest of the lighting To switch On Off the lamp please refer to Switching On Off the lamp menu LAMP Note It is also important to note that the discharge lamp is cold restrike types that means that they have to be cold before re striking For th...

Page 14: ... 15 21 28 provided by the special multistep zoom 3 steps Dimmer Shutter Strobe Smooth 0 100 dimming is provided by the combined mechanical dimmer shutter unit This unit may also be used for strobe effect 1 10 flashes per second Fans The SCAN 1200 XT is cooled by an axial fan situated at the rear side of the lighting The speed of the fan of course the noice can be continuously reduced if very quiet...

Page 15: ...he program step No 1 when requested by the master For example If the slave fixture has a shorter program length it will continously repeat its program until the master fixture finishes its own program and restarts its program running slave 1 prog step 3 will not be finished If the slave fixture has a longer program length it will restart at prog step 1 before it completes all its prog steps slave ...

Page 16: ...utton so many times until the display shows message A001 with actually stored address 2 Press Enter button and use the Up and down buttons to select dM Ad menu 3 Press Enter button the letter A flashes and by Up and down buttons select required address 001 497 press Enter button to confirm 4 Select M ASL menu press Enter button and use Up and down buttons to select d AbL no master or slave press E...

Page 17: ...2 Slave control This function allows you to control the slaves from the master s control panel in a master slave operation Select this function from the main menu and press Enter button Browse the list of all connected slaves SL C 1 SL C 9 by pressing Up or Down button Select the desired slave and press Enter button The slave s control panel is available from the master s control panel If no slave...

Page 18: ...lamp strikes since the counter was last reset Press Enter or Mode to return to the menu In order to reset the counter to 0 you have to hold the Up and Down button and press the Enter button Max fixture head temperature By this option you can read the max temperature of the head inside since the SCAN 1200 XT has been fabricated Press Enter or Mode to return to the menu Max temperature of the head i...

Page 19: ...you to invert the tilt movement Use the Up and Down buttons to select On if you wish this feature or Off if you don t wish this feature and press Enter to confirm or Mode to cancel and return to the menu Movement resolution By this function you can adjust the 16 bit movement resolution Mod 1 Mod 2 or 8 bit resolution 8bit Use the Up or Down keys to select the desired movement resolution and press ...

Page 20: ...to select On if you want to switch off the lamp by DMX or Off if you don t want to switch off the lamp by DMX and press Enter to confirm or Mode to cancel and return to the menu Lamp On if DMX is present This function allows you to strike the lamp automatically after 26 seconds if DMX signal is present on the data link If the ignition is unsuccessfull e g lamp is too hot the fixture will try to ig...

Page 21: ...the display intensity and press Enter to confirm or Mode to cancel and return to the menu Display reverse With this function you can rotate the display by 180 Use the Up and Down buttons to select normal display or display turned by 180 and press Enter to confirm or Mode to cancel and return to the menu Display On This function allows you to keep the display on or to turn off automatically 2 minut...

Page 22: ...then the SCAN 1200 XT automatically switches off the lamp Low high speed of the fan operating The fan keeps the adjusted low speed until the temperature exceeds max inside temperature of the fixture then the SCAN 1200 XT automatically switches from low to high the fan speed Note The modes Auto and HIGH don t interact to the DMX value on the channel 6 0 127 Default settings Press Enter to reset all...

Page 23: ... Up and Down keys to select the Mod1 or Mod2 sequences The Mod1 is suitable for projections on the wall ceiling or ground without any mirror movement the Mod2 uses all SCAN 1200 XT functions and therefore is good for a complete introduction of the fixture Select Mod1 or Mod2 by Up and Down buttons and press Enter to confirm the choice If the test program is running messages run test blink on the d...

Page 24: ...nter button again Note If the fixture operates in the controller mode DMX controller is connected and any program from this function is selected in this case the fixture will not respond to the DMX controller and will play selected program You can t play programs on the slave fixtures from their control panels if the master fixture is switched On and connected to the slaves playing is forced by th...

Page 25: ... PrG 2 PrG 3 are saved in the current modified fixture master or slave1 9 8 8 Reset function Press Enter button to run a reset This option enables the SCAN 1200 XT to index all effects functions and return to their standard positions 8 9 Special functions Use the Up and Down buttons to browse through the special functions and select the one by pressing Enter Manual control of effects The function ...

Page 26: ...t FCAL function Fixture calibration 1 Calibration via the control board Press Enter and the Up and Down keys in order to display the following messages Col1 Col2 EFEC SGob rGob for very smooth function calibration Select one of them press Enter and use the Up and Down keys in order to adjust their right value from 0 to 255 Then press Enter to confirm or Menu to cancel and return to the menu This c...

Page 27: ...play shows LAEr meaning that the lamp could be damaged or even missed the fixture is overheating this can occur if the ambient temperature is 45 C or more or there could be a failure on the ignitor or ballast Please place or replace the lamp check the ambient temperature or contact your dealer if the situation was not caused by the lamp FAn The message informs you that the fixture was overheating ...

Page 28: ...r magnet missing or the stepper motor is failed or its driver circuit on the main PCB The rotating gobo is not after the reset in the default position EFEr effect wheel error This messsage will appear after the reset of the fixture if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepper motor is failed or its driver circuit on the main PCB The effect wheel is n...

Page 29: ...ndensor lens with high efficiency parabolic mirror focus lens and multistep zoom lenses system 15 21 28 beam angles Colour wheel 1 8 dichroic filters plus white colour wheel with variable rotation speed Colour wheel 2 5 dichroic filters colour temperature filters 3200 K and 5600 K UV filter plus white Static gobos 5 metal gobos plus open outside diameter 53 3mm image diameter 40mm stainless steel ...

Page 30: ...fferent beam angles 15 21 28 provided by the special multistep zoom 3 steps Electronics Built in analyzer for easy fault finding error messages Bilt in demo sequences Master slave operation Silent fan cooling remotely controllable speed of fan Self resetable thermo fuse Digital serial input DMX 512 16 control channels full 16 bit protocol Channel Mode 1 16bit default Mode 2 16bit 8 bit 1 Pan Pan P...

Page 31: ... will require weekly cleaning as smoke fluid tends to building up residues reducing the light output very quickly The cooling fan should be cleaned monthly The gobos may be cleaned with a soft brush The interior of the projector should be cleaned at least annually using a vacuum cleaner or an air jet The dichroic colour filters the gobo wheel and the internal lenses should be cleaned monthly To en...

Reviews: