4
The two items of this menu help you to keep cleaning period of the air filters.
Alert period
- Cleaning schedule for the fixture depends on the operating environment.
It is therefore impossible to specify accurate cleaning interval. This item allows
you to change the cleaning interval of the air filters. This "alert" value is 300 hours and it
is set as default. Inspect the fixture within its 300 hours of operation to see whether cleaning
is necessary. If cleaning is required, clean all air filters and change the value in this menu
on acceptable level. Min. level of alert period is 10 hours, max. is 300 hours.
Elapsed Time
- The item allows you to read the time which remains to cleaning air filters.
The time period is set in the menu mentioned above.
Expired time period is signalled by a negative mark (-) at the time value and a warning icon
on the display.
Clean the filters and reset this menu item (by touching the text box next to the item
"Elapsed Time").
Fixture Temperatures
- The menu is used to view temperatures of the fixture´s inside.
Head Temperature
- The menu shows temperatures in the fixture head near the lamp.
Current
- A current temperature of the fixture head.
Maximum NonRes.
- A maximum temperature of the fixture head since the fixture has
been fabricated.
Maximum Res.
- A maximum temperature of the fixture head since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
Note:
if the "Head Temperature" exceeds 115°C, the lamp will be switched off.
Base Temperature
- The menu shows temperature in the fixture base (on the display PCB).
Current
- A current temperature in the fixture base.
Maximum NonRes.
- A maximum temperature in the fixture base since the fixture has
been fabricated.
Maximum Res.
- A maximum temperature in the fixture base since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
Ambient Temperature
- The menu shows temperature of the induced air on the fan in the fixture base .
Current
- A current temperature of the induced air in the fixture base.
Maximum NonRes.
- A maximum temperature of the induced air in the fixture base since
the fixture has been fabricated.
Maximum Res.
- A maximum temperature of the induced air in the fixture base since
since the counter was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
DMX Values -
The menu is used to read DMX values of each channel received by the fixture.
Wireless State -
The menu serves for reading of the wireless operation status
Unlink Wireless Adapter
- The menu item allows unlinking the fixture from the transmitter .
Power Channel State -
The menu item shows state of the Power/Special functions switches.
Software Version
- Select this item to read the software version of the fixture modules:
Display System
- A display processor on the display board in the fixture base
Module M
- A pan/Tilt
Module G
- A rot. gobo wheel , animation wheel rotation
Module P
- A prism, frost
Module O
- A zoom, focus
Module I
- An iris, gobo wheel , animation wheel
Module C
- A CMY+CTO module
Module D
- A dimmer, lamp fans
Module S
- A shutter, colour and colour
Product IDs -
The menu is used to read the MAC Address ,RDM UID and RDM Label.
View Logs
- Use this menu to read fixture´s data which have been recorded during fixture operation. This col
-
lected data allows easier troubleshooting.
Fixture Errors
- Use this menu to read fixture errors which have occurred during fixture operation.
There is a list of error messages:
Pan Error
Prism Error
Tilt Error
Prism Rotation Error
Summary of Contents for BMFL Robin Spot Woreless DMX CRMX
Page 1: ... Version 1 3 ...
Page 40: ...40 Photometric diagrams ...
Page 41: ...41 ...
Page 56: ......
Page 57: ...43 ...