Replacing SteelConnect SDI-2030 and SDI-5030 Gateway Components | 33
Replacing fans
2. Press the release tab toward the black handle, and pull the power supply unit toward you.
Figure 3-15. Removing the power supply unit
Power supply 1 (PS1) is on the left, and power supply 2 (PS2) is on the right.
3. Pull the power supply unit out of the chassis.
Caution:
Put the defective power supply unit aside; wait until it cools down before touching it.
4. Slide in the new power supply unit until it clicks into place.
Figure 3-16. Inserting the power supply unit
5. Plug the AC power cord into the new power supply unit.
Replacing fans
This section describes how to replace fans in the gateway. The gateways are equipped with six fans that
are not hot swappable. You must power down the gateway before replacing the fans.
Note:
You must use approved fans. To order fans, contact Riverbed Support at
https://support.riverbed.com
.