48
2 - I
NSTALLING
AND
D
EPLOYING
S
TEELHEAD
M
OBILE
2. Deploying Steelhead Mobile in Environments with Firewalls
If you need a solution for remote access users only, a location for the Mobile Controller might be in the DMZ
next to a VPN concentrator with firewalls on each side. Users who need access to the Mobile Controller can
connect to it from outside the DMZ zone. This scenario requires that the client-side network firewall have
port
7801
available. The server-side firewall must have ports
22
,
80
,
443
,
7800
and
7870
open.
If you are using application control, you need to allow
rbtdebug.exe
,
rbtmon.exe
,
rbtsport.exe
, and
shmobile.exe
.
Figure 2-2. Steelhead Mobile Deployment in the DMZ
3. Installing on a Rack
If your model has a bezel, remove it.
Align the screw holes on the flanges with the screw holes on the rack.
Insert and tighten the screws on each side of the appliance.
4. Connecting the Power
If your model has a master power switch, make sure it is in the off position (on the rear panel).
Plug the power cord or cords into the Mobile Controller and an AC outlet.
If your model has a master power switch, press in the master power switch (ON).
Press in the system power switch on the front of the Mobile Controller.
CAUTION:
In all European electrical environments, you must ground the Green/Yellow tab on the power cord. If you
do not ground the Green/Yellow tab, it can cause electrical shock.