FB ORIGINAL SCANNING SECTION
[ 12 - 12 ]
Disassembly
1. Removing the Scanner Unit
(1) Start the Test Mode No. 154 (Scanner Lock Action) to move the carriage to the lock position, open
the scanner table, secure the mirror carriage with the screws used for equipment transport, and
then close the scanner table.
(2) Switch off the power, and remove the following covers:
• Rear cover
• Stage cover (if equipped with AF and digitizer, remove them also.)
• Scanner-unit cover, left
• Scanner-unit cover, rear
• Scanner-unit cover, front
• Scanner-unit cover, right
< RN25 Series >
(3) Disconnect the two control-panel connectors, remove the five mounting screws (RS tight, M4 x 8),
and then remove the control panel. (This is done to prevent damage to the control panel.)
(4) Disconnect the FB read pulse motor and FB/AF HP sensor connectors from the scanner unit.
Disconnect the three connectors from the SCAN-IF400-PCB.
(5) Remove the cover-open sensor ass’y with one screw (double-washer, M4 x 8), and disconnect the
connector.
(6) Remove the four screws (double-washer, M4 x 8) securing the scanner unit to the hinge plate.
(7) Remove the six screws (double-washer, M4 x 8) from the scanner unit, and then remove the
scanner unit by lifting it upward. (This is a heavy precision component. Handle with care.)
< RN20/21 Series >
(3) Detach the two connectors from the scanner unit. (Flat cables on main PCB connectors)
(4) Remove the two screws (double-washer, M4 x 8) on the two stage cover brackets that secure the
scanner unit.
(5) Remove the stage cover sensor assembly with the screw (double-washer, M4 x 8).
(6) Remove the six screws (double-washer, M4 x 8) on the scanner unit, and remove the unit upwards.
(Take care when handling, as this is a heavy precision unit.)
[Precautions on Reassembly]
• After reassembling, open the scanner table and remove the transport lock screw on the mirror
carriage. Clear the error message using Test Mode No. 155 (Scan Release Action).
< RN20/21 Series >
• When mounting the scanner, align the half-pierced sections of the two front alignment brackets and
those on the two Stage cover brackets.
< RN25 Series >
Prior to reassembly, write down the information on the label at the right side of the top panel of the
scanner unit. Following reassembly, activate the factory-testing mode and set the scanner.
Summary of Contents for RP-255
Page 22: ...MAINTENANCE 1 9 NOTE...
Page 27: ...MAINTENANCE 1 14 MEMO...
Page 45: ...MACHINE SUMMARY 2 8 Memo...
Page 50: ...MAIN DRIVE SECTION 3 5 Memo...
Page 83: ...FIRST PAPER FEED SECTION 4 26 Memo...
Page 108: ...PRESS SECTION 6 9 Memo...
Page 111: ...PRESS SECTION 6 12 Memo...
Page 169: ...PRINT DRUM SECTION 8 30 Memo...
Page 197: ...FB ORIGINAL SCANNING SECTION 11 2 Memo...
Page 213: ...FB ORIGINAL SCANNING SECTION 12 2 Memo...
Page 222: ...FB ORIGINAL SCANNING SECTION 12 11 Memo...
Page 271: ...AF SCANNING SECTION RN20 21 Series 14 18 Memo...
Page 295: ...MASTER MAKING SECTION 15 24...
Page 303: ...TIMING CHARTS 16 8 Memo...
Page 399: ...TEST MODE 18 32 Memo...
Page 405: ...MISCELLANEOUS PRECAUTIONS 19 6 Memo...
Page 423: ...ELECTRICAL DIAGRAMS RN25 Series 20 18 Memo...
Page 439: ...RISO Inc Technical Services Support US RISO COM ELECTRICAL DIAGRAMS RN20 21 Series 21 16 Memo...
Page 441: ...ELECTRICAL COMPONENTS 22 2 O A B C D E F G H I J K L M N 2201 2202 1 Motors...
Page 443: ...ELECTRICAL COMPONENTS 22 4 A B C D E 2203 2204 2 Fans Solenoids Electromagnetic Clutch...