70
ProSYS Installation and Programming Manual
22
44
Zones: Zone Sound
The Zone Sound menu
contains parameters that enable you to program the sound produced
when a system zone triggers an alarm. Reports to the MS are not affected by any of the
options in this menu.
To access the Zone Sound menu:
1
Access the Zones menu, as described on page 62.
2
From the Zones menu, press [4] to access the Zone Sound menu options. The following
display appears:
3
Specify a two-digit zone number and press
/
.
4
Access and configure the parameters in the Zone Sound menu, as follows:
Zones: Zone Sound
Quick Keys
Parameter
Default
22
44
ZZ
ZZ
+
/
11
Silent
Produces no sound.
22
44
ZZ
ZZ
+
/
22
Bell Only
Activates the bell sounders for the duration of the Bell Timeout period, or
until a User Code is entered, followed by use of the
/
key.
22
44
ZZ
ZZ
+
/
33
Buzzer Only
Activates each keypad's internal piezo buzzer.
22
44
ZZ
ZZ
+
/
44
Bell + Buzzer
Default for all zones
Activates the bell sounders and the keypads' buzzers simultaneously.
22
44
ZZ
ZZ
+
/
55
Door Chime
The
Door Chime
parameter is used as an audible sounder to indicate the
violation of a zone(s), as follows:
If the system is DISARMED, the system's keypad buzzers make three
momentary sounds whenever the zone is violated.
If the system is ARMED, only the bell sounders will produce the alarm.