ProSYS Installation and Programming Manual
127
Dialer: Report Split
Quick Keys
Parameter
Default
55
77
44
FM
11
44
ACM Mail
Events are reported to the Follow Me destination by E-mail using the ACM
module.
NOTE:
Only Follow Me numbers 1 and 2 can be defined as ACM Mail.
55
77 44
FM
22
Follow-Me Partition
Specify the partitions that will initiate the Follow-Me report due to a certain
event that occurred in the assigned partitions.
NOTE:
Follow Me numbers 1 through 8 are assigned partitions 1 through 8,
respectively by default. Follow Me numbers 9 through 16 are not assigned
partitions by default. Ensure that they are assigned partitions otherwise the end
user will not see them in the list of available Follow Me numbers.
1. Use the keys
[1 to 8]
keys to assign the partitions.
2. Press
/
.
55
77
44
FM
33
Follow-Me Events
Specifies which events will activate this Follow-Me destination in the
partitions assigned to the Follow-Me destination.
Use the
/
or
/
keys to select the events from
the list below, and then use the
/
and
/
keys
to select
[Y] YES
or
[N] NO
.
[01]
Intruder Y
[02]
Fire Y
[03]
Emergency Y
[04]
Panic Y
[05]
Tamper N
[06]
Remote
Programming
N
[07]
AC Off
N
[08]
Duress Y
[09]
Arm N
[10]
Disarm N
[11]
Bypass N
[12]
Wireless Lost
N (When no supervision signal from the wireless
zones is received.)
[13]
Wireless Low
Batt
N (wireless zone or keyfob)
[14]
Bell Trouble
N
[15]
False Code
N (When a wrong User Code is entered more
than 3 times.)