ProSYS Installation and Programming Manual
69
Zones: Zone Type
Quick Keys
Parameter
Default
Arming Level/Range
This type of zone is used to avoid a false alarm by acting like an Exit
(OP)/Entry zone (see
Exit (OP)/Entry
, page 66).
When triggered (after arming the system and closing the door
or
opening the
door, arming the system, and closing the door), the system's Exit Delay time
period will be shortened to 3 seconds.
When you re-open the door, the entry time restarts.
22
33
ZZ
ZZ
+
/
19
19
Latch Keyswitch
Connect an external SPST latched (non-momentary) keyswitch to any zone
terminals given this designation and operate the keyswitch, as follows:
After arming one or more partitions using the keyswitch and then disarming
using the keypad, the related partitions will be disarmed. In order to arm
the partition using the keyswitch again, turn the key to the disarm position
and then to the arm position.
If a keyswitch latch is assigned to more than one partition and one of the
partitions is armed by using the keypad (the keyswitch stays in the disarm
position), then:
When changing the position of the keyswitch to the arm position, all the
disarmed partitions, which belong to this keyswitch, will be armed.
When turning the keyswitch to the disarm position, all the partitions will
be disarmed.
22
33
ZZ
ZZ
+
/
20
20
Entry Fo Stay
All
Assigned to motion detectors and to interior doors protecting the area between
the entry door and the keypad, as follows:
In STAY (ARM) mode, a zone(s) given this designation behaves like an
Exit/Entry zone and is subject to the Entry and Exit Delay time periods
specified under Exit/Entry Delay 1. (Refer to Exit/Entry Delay 1, page 47.)
In AWAY (ARM) mode, a zone(s) given this designation behaves like an Entry
Follower Zone and causes an immediate intrusion alarm when violated
unless an Exit/Entry zone was violated first.
If so, an Entry Fo Stay zone(s) remains bypassed until the end of the
Entry Delay period.
22
33
ZZ
ZZ
+
/
21
21
Keyswitch Delay
Used to apply the
Exit/Entry Delay 1
parameter to the momentary keyswitch
operation. (Refer to
Keyswitch
, page 68.)
22
33
ZZ
ZZ
+
/
22
22
Latch KSW Delay
Used to apply the
Exit/Entry Delay 1
parameter to the latched keyswitch
operation. (Refer to
Latch Keyswitch
, page 69.)