ProSYS Installation and Programming Manual
43
Keypad Timeout
If, after 15 minutes, no entry is made to a keypad that has been placed in the Installer
Programming mode, it will produce an audible reminder, consisting of several beeps in rapid
succession, along with the following display:
Pressing any key stops the beeping. To re-enter the Installer Programming menu, you must
key in your Installer code again and press
/
.
Using the Program Transfer Module (PTM)
The Program Transfer Module (PTM)
is used to create and apply standard programming
templates.
In addition, you can use the PTM
on powered-up, properly functioning Main Panels, which
have been previously programmed.
To create a Programming Template by copying from a programmed Main Panel:
♦
Use a programmed Main Panel to create a Programming Template to be applied to other
Main Panels. The programming on the Main Panel is ready for copying.
To install a Programming Template on a Main Panel:
♦
Use an existing Programming Template on a PTM to install programming on a Main Panel.
At least one LCD keypad must be installed on the Main Panel.
To copy from a programmed Main Panel into the PTM:
1
Position the PTM on the J1, J5 or J8 connector on the Main Panel with the red LED facing
the row of terminals on the Main Panel. The red LED flashes slowly.
2
Remove the J2 jumper plug from its position on one pin of the J2 connector.
3
Position the J2 jumper plug on both of the two pins of the J2 connector.
4
From an LCD keypad, access the main Installer Programming menu by pressing
[7] [1]
. The first option of the main Installer Programming menu is displayed.
5
Without making any changes, exit the main Installer Programming menu by pressing
[0]
.
The LED on the Program Transfer module flashes rapidly, and the keypad displays the
following:
When the LED stops flashing rapidly, the keypad beeps twice and displays the following:
Then the keypad returns to the normal initial display.
6
Remove the PTM from the J1, J5 or J8 connector and remove the J2 jumper plug.
7
Position the J2 jumper plug on one of the pins of the J2 connector.
The PTM now contains a copy of the Main Panel's configuration.
To load the Program Transfer Module’s stored configuration into a Main Panel:
1
Position the PTM on the J1, J5 or J8 connector on the Main with the red LED facing the
row of terminals on the Main Panel. The red LED flashes slowly.