background image

17

CONTROl paNEl OpERaTiONS

1

keypad settings

keypad lock/unlock (optional)

When this option is enabled, the user can partially 

or completely lock the keypad. 
When Full Lock is selected, all functions are 

locked.
In Partial Lock, you may only activate accessories. 

Settings may not be changed in this mode.

keypad color (optional)

If this option is available (depending on the spa 

configuration), the keypad rim color can be 

changed. 
8 pre-defined colors are available. If the in.mix 

is installed, the keypad rim color can also be 

associated to an in.mix zone.

When the user wants to lock the keypad he is 

asked to select a 4-digit code. The same code will 

be needed to unlock the keypad.

Next time he wants to lock the keypad, he will be 

prompted again to select a 4-digit code (same 

functionality as a Safe in a hotel room).
The keypad can be unlocked with a universal 

unlock code (3732) or by a reset of the keypad.

miscellaneous

This menu gives access to modify the Warm 

Weather option and info messages in the media 

center.

warm weather

The Warm weather option allows you to bypass 

the pack filtration over-temperature feature. 

When Warm weather is On, the filtration over-

temperature is disabled. This feature allows the 

spa to continue filtering even though the water 

temperature is high.

info messages

Press display/hide key to modify message display:
If hide option is selected, smart winter mode 

message will only appear when a SWM purge is in 

action. Otherwise the message will always appear 

when the spa is in a SWM condition.
If hide option is selected, heating suspended and 

filtering suspended messages will not appear.

miscellaneous

Summary of Contents for Nautilus 5.8

Page 1: ...Riptide Nautilus 5 8 IN GROUND EXERCISE POOLS Owner s Manual...

Page 2: ...ation 18 Audio mode 19 On off 19 Speakers setting 19 Audio source selector 19 Disconnect Bluetooth 19 Variable speed drive control panel 20 Other functions 20 Freeze protection 20 Clean cycle 20 Circu...

Page 3: ...Riptide Nautilus 5 8 TURBO IN GROUND 3 Riptide nautilus 5 8 turbo Riptide nautilus 5 8 turbo Pro...

Page 4: ...a a The use of alcohol drugs or medication can greatly increase the risk of fatal Hypothermia in a pool b The causes symptoms and effects of Hypothermia may be described as follows Hypothermia occurs...

Page 5: ...excessive water may contact the pool such as from sprinklers or a roof edge without rain gutters If possible avoid areas of direct prolonged sunlight The ultraviolet rays of sunlight will tend to fad...

Page 6: ...er from over filling the pool Excess water will flow out from the corner adjacent to the overflow Note 1 The higher the water level the less pool users it will take to cause the water to overflow the...

Page 7: ...ough the service hatch to repair or replace as needed The only consideration here is that your electrician will need to supply a suitable cable with a waterproof gland to pass through the fiberglass w...

Page 8: ...pool base Ensure that the ground around the pool is drainable if not then large soakaways should be constructed to ensure the pool will not flood To avoid the pool floating if any underground water i...

Page 9: ...il paving slabs decking or tiles as required Covers Covers are essential for keeping your pool both clean and the water hot You can sink your pool up to the lip like the pool installation in the photo...

Page 10: ...DIAGRAMS 10 Riptide nautilus 5 8 TURBO 1 3HP Single Speed Pump 2 Control Box 3 Ozone Clear Core Chamber 4 Ozone Generator 5 Circulation Pump 6 Control Panel...

Page 11: ...gle Speed 5 1 Air Check Valve Assembly 6 Two Cylinder Skimmer 7 2 Suction 8 Ozone Injector 9 Swim Jet 10 5 Light Housing 11 2 Infinity LED 12 Large Face Direct Jet Insert 13 Stainless Steel Handrail 1...

Page 12: ...anytime you wish The Gecko in k1000 capacitive touch screen display keypad fitted to the Nautilus range will operate under wet and rainy conditions Jet control The speed of the jets is fully adjustabl...

Page 13: ...s the following modes sanitization with in clear connected audio with in stream 2 connected color with in mix installed spa settings To select a mode slide the left wheel up or down until the desired...

Page 14: ...e the right wheel until the display contrast icon is highlighted in the middle Simply touch the line of the contrast you want to select water temperature The temperature at the bottom of the screen sh...

Page 15: ...pump configured to run 24 hours the screen will show you the purge setting instead of filtration The purges are pre programmed for a fix number of minutes therefore the duration will be set to N A on...

Page 16: ...to reset the time once a task has been completed To reset a task select it by pressing the curved arrow then confirm when prompted Once you have confirmed the task will be reset set date Here you can...

Page 17: ...d he will be prompted again to select a 4 digit code same functionality as a Safe in a hotel room The keypad can be unlocked with a universal unlock code 3732 or by a reset of the keypad miscellaneous...

Page 18: ...en check mark Swipe Up or Down the list to select your network wifi network password If the wifi network is password protected enter it when keyboard prompts Use Enter key to validate the password If...

Page 19: ...e fade and subwoofer sliders will only appear on the screen if the corresponding speakers are installed on the in stream 2 turn in stream 2 OFF icon green Press the icon at the center of the screen to...

Page 20: ...e control Freeze Protection If the sensors within the heater detect a very low temperature the pumps and blower automatically activate to provide freeze protection The pumps and blower will run contin...

Page 21: ...m incompatible RH NC Comm error between in xm2 in therm SC ER Error detected during the learning mode SP in Input voltage issue Supp Connect power cord to 240 V source UPL The spa pack does not have v...

Page 22: ...Electric control failure display shows error message The default time setting has switched off the jets The pump motor is overheating The water pump has an air block Filter cartridge needs cleaning Th...

Page 23: ...SHOCK or double dose of CHLORINE GRANULES MAINTENANCE 3 pH Control Proper pH balance is extremely important in controlling bacteria providing water that s comfortable for the user and in preventing da...

Page 24: ...s per million 5 Test and adjust the pH to the range of 7 2 7 6 6 After the water has circulated for approximately a quarter of an hour retest the chlorine level in your water and add the correct amoun...

Page 25: ...Volume Alkalinity Chemical Addition Total alkalinity adjustment required in mg L Metre Effect 10 20 30 40 50 60 70 80 90 100 NAUTILUS 5 8 IN GROUND 9 560 Reduce Sodium Bisulphate pH Reducer 229 44g 4...

Page 26: ...HEADRESTS Clean on a regular basis with soap water and a clean cloth Use 303 Protectant or it s equivalent once per month This will maintain water resistance and lustre of the product Between uses it...

Page 27: ...level No use for 1 2 weeks If you plan to not use your pool for 1 2 weeks then we suggest that you not make any changes in operating your pool No use for 2 6 weeks If you plan to not use your pool fo...

Page 28: ...www riptidespas com...

Reviews: