Rinnai
22
Installation Manual
HEATER INSTALLATION
4. HEATER BODY INSTALLATION
Carefully move the appliance body into the enclosure cavity
ensuring that both the consumer piping and flue transition are
aligned with their access openings.
As the appliance is pushed home ensure that the flexible gas
connection
coils freely inside the appliance and that the
consumer piping penetrates through the centre of the gas access
point .
Securing The Heater Body
Once the heater is in position open both air return louvre doors to
gain access to the appliance mounting points
.
The upper and lower mounting points (four in total) are located on
each side of the appliance.
Secure heater body through these points using appropriate
fixings.
5. CONNECTING THE FLUE SYSTEM TO THE APPLIANCE
Only Rinnai RHFE-752ETR flue components MUST be used with this appliance.
Connections between the heater and the flue system MUST BE made in accordance with the
Rinnai “Power Flued Flamefire Space Heater Co-axial Flue System Installation Manual”
supplied with flue kits ASPDFK or ASPKIT03.
Ensure the flue spigot of the heater is properly secured to the flue connection on the flue
system transition casting using the clip and clamp provided.
If this joint is not secured properly products of combustion could disperse into the room
being heated which may result in a dangerous condition.
Ensure the elbow of the air intake hose from the heater is properly secured to the air
connection on the flue system transition casting using the cable tie provided and that the
rubber seal is placed on the unused air intake connection of the transition piece.
6. CLOSING THE FLUE SYSTEM ACCESS PANEL
Once the flue and air connections are secured slide
the flue system access panel
back into position
and fasten
(two screws).
The hole in the flue system access panel is offset and
can be reversed (flipped) as shown to align the
position of the heater flue spigot with the flue system
transition casting.
C
D
H
D
C
H
IMPORTANT
G
E
F
E
F
G