Operation Manual
PROGRAMMED HEATER OPERATION
PROGRAMMING THE CLOCK AND TIMERS
The clock must be set before the timers will operate. The clock may need to
be re-set whenever the remote control batteries are changed. This heater has
two timers which allow the heater to start and stop during two distinct periods
each day. The set temperature during timer operation is the temperature
which was selected when the heater was last used.
Clock Setting
1. Press the Time Set
button once. "Clock Set"
will be displayed to
confirm that the function has been initiated. The Remote Display will
show "AM 12:00"
.
2. Use the Up and Down
buttons to set the desired "AM" or "PM" clock
time. Then press the Time Set
button once.
If you do not want to set the timers at this point then press the
Time Set
button 4 more times until the display returns to
the time. If there is no button pressed for approximately 90
seconds then the screen will deactivate and any settings that
have not been transmitted will be lost.
Timer Setting
3. "Timer 1 Set ON"
and "AM 06:00"
will be displayed. Use the Up
and Down
buttons to set the desired "AM" or "PM" "ON" time. Press
the Time Set
button once.
4. "Timer 1 Set OFF"
and "AM 09:00"
will be displayed. Use the Up
and Down
buttons to set the desired "AM" or "PM" "OFF" time. Press
the Time Set
button once.
5. To set-up Timer 2 repeat steps 3. and 4 above or just press the Time Set
button three times to exit the timer set-up.
6. The set On/Off timers will be displayed briefly to confirm settings.
When the programs have been received the Remote Display will revert to
Time mode
and
.
After battery replacement the clock and timers may need to
be re-programmed.
PRE-HEAT
This function operates automatically in conjunction with the Timers. When a Timer is selected, the
heater may operate anywhere within an hour prior to the programmed ON Time.
This function is called Pre-heat as it ensures the room reaches
the desired temperature by the programmed ON time. This is
achieved by sensing the rooms temperature one hour prior to
start.
The difference in room and set temperatures at the time of
sensing the room temperature determines exactly how long
before the programmed ON time the micro-computer will ignite
the burner.
18
25
23
12
18
STANDBY
ON
Flame
Extra
Low
Lock
Timer 2
Timer 1
Overide
Time
Set
Temperature
Lock
Clock
AM
PM
Timer 1
Set
Set
ON OFF
ON OFF
Timer 2 Set
OverrideAuto Off
Time
Flame
20
21
14
15
16
17
19
18
11
13
12
Temperature
Lock
Clock
AM
PM
Timer 1
Set
Set
ON OFF
ON OFF
Timer 2 Set
Override Auto Off
Time
Flame
23
25
Temperature
Lock
AM
PM
Timer 1 Set
ON
OFF
ON OFF
Timer 2 Set
Override Auto Off
Time
Flame
23
26
Temperature
Lock
AM
PM
Timer 1 Set
OFF
ON OFF
Timer 2 Set
Override Auto Off
Time
Flame
23
26
Temperature
Lock
AM
PM
ON OFF
Timer 2 Set
Override Auto Off
Time
Flame
23
24
NOTE
18
26
23
12
18
26
23
12
18
18
23
24
NOTE
7:00
6:30
6:00
Timer
programmed
ON time
Room
temperature
sensed
Earlier than
usual ignition
Later than
usual ignition
Average
ignition
Cooler than usual
Warmer than usual
Average starting time
Time elapsed from ignition to pre-set temperature
Recorded by Micro-computer