Rinnai Tankless Water Heater Installation and Operation Manual
59
Table 26: Pressure Drop 3.0 in. wc
Intended use: Initial supply
pressure of 8.0 in. wc
or greater.
Information in table
obtained from NFPA 54,
ANSI Z223.1 - 2021.
Nominal Pipe Size (in.)
1/2
3/4
1
1 1/4
Length in ft (meters)
Capacity in Cubic Feet of Gas per Hour
10 (3)
454
949
1,790
3,670
20 (6)
312
652
1,230
2,520
30 (9)
250
524
986
2,030
40 (12)
214
448
844
1,730
50 (15)
190
397
748
1,540
60 (18)
172
360
678
1,390
70 (21)
158
331
624
1,280
80 (24)
147
308
580
1,190
90 (27)
138
289
544
1,120
100 (30)
131
273
514
1,060
Natural Gas
Table 27: Example
Rinnai Model Gas Input:
Additional Appliance Total Gas Input:
Heating Value of Gas:
Cubic Feet Per Hour (CFH):
Answer:
For this example, the pipe diameter
must be at least 1/2 in. pipe size and
20 ft (6 m) in length.
A
199,000
Btu/hr
B
65,000
Btu/hr
C
1,000
Btu/ft
3
(CFH)
=
A + B
C
(CFH)
=
199,000+65,000
1,000
(CFH)
=
264
ft
3
/hr
Schedule 40 Metallic Pipe
Inlet Pressure:
Less than 2 psi
Specific Gravity:
0.60
Propane (Undiluted)
Table 28: Pressure Drop 0.5 in. wc
Information in table obtained from
NFPA 54, ANSI Z223.1 - 2021.
Nominal Pipe Size (in.)
1/2
3/4
1
1 1/4
Length in ft (meters) Capacity in Thousands of Btu per Hour
10 (3)
291
608
1,150
2,350
20 (6)
200
418
787
1,620
30 (9)
160
336
632
1,300
40 (12)
137
287
541
1,110
50 (15)
122
255
480
985
60 (18)
110
231
434
892
70 (21)
101
212
400
821
80 (24)
94
197
372
763
90 (27)
89
185
349
716
100 (30)
84
175
330
677
Schedule 40 Metallic Pipe
Inlet Pressure:
11 in wc
Specific Gravity:
1.50
Table 29: Example
Rinnai Model Gas Input:
Additional Appliance Total Gas Input:
Total Gas Input:
Answer:
For this example, the pipe diameter
must be at least 1/2 in. nominal pipe
size and 10 ft (3 m) in length.
A
199,000
Btu/hr
B
65,000
Btu/hr
Total Gas
Input
=
264,000
Btu/hr
Total Gas
Input
=
A + B
Total Gas
Input
=
199,000 + 65,000