Rinnai
30
ES_FIM
CONNECTING CONDENSATE DRAIN TUBE TO HEATER
1.
Condensate trap “ESCONDK”.
2. Carefully mark and drill a 16 diameter mm hole through both the heat shield panel and
appliance back panel.
DO NOT
allow the drill to penetrate further than 10 mm past
the back panel as damage to the heat exchanger or internal components will occur.
CAUTION
To insert the condensate drain hose in the appliance drill through both the
raised heat shield and the heater back panel.
A 16 mm diameter hole is required for the correct clearance with the
condensate drain hose supplied.
DO NOT
allow the drill to penetrate further than 10mm past the back panel
as damage to the internal components such as the heat exchanger will
occur.
WARNING
UNDER NO CIRCUMSTANCES MUST THE APPLIANCE BE OPERATED WITH A
DAMAGED HEAT EXCHANGER
NOTE
The condensate drain tube pipe and the pipe clip are available as a spare part from Rinnai, part
number 90180944.
2
90
120
RHFE-308FTR
75
120
RHFE-309FT/FT2
65
80
RHFE-556FTR/FDT
115
120
RHFE-557FTR
RHFE-561FT/FT2
80
RHFE-559FT/FDT/FT2/FDT2
115
Dim ‘B’
*Dim ‘A’
*Dim ‘A’ Dim ‘B’
RHFE-1004FTR/FDT
510mm
135mm
500mm
100mm
Heat
Shields
*
Heat Shield
Heat Shield
Heat Shield
Heat Shield
Heat Shield
Back panel
Back panel
Back panel
Back panel
Back panel
Back panel
RHFE-1005FT/FDT/FT2/FDT2
*
Drill the lower heat shield
ONLY!
All vertical measurements are from floor level.
* The horizontal measurements are taken from the edge of the raised back panel.
3.
Feed approximately 60mm of the free end of the drain tube through the drilled holes created in step 2. above.
Ensure that any condensation can drain into the condensation tray of the heater.
CAUTION
DO NOT
allow any portion of the drain tube to come into contact with any part of the heat
exchanger.
DO NOT
kink, crimp or sharply bend any portion of the condensate drain tube.
4. Secure the drain tube to the rear of the appliance with a pipe clip, (clip not included).
Drain Tube*
Rubber
Drain
Outlet
*Drain tube & clamp
1
spare part No. 90180944)
INSTALLATION METHODS
Summary of Contents for ENERGYSAVER RHFE-308FTR
Page 31: ...Rinnai 31 ES_FIM NOTES ...