Rinnai
27
ES_FIM
6.
Pass the combustion air hose of the heater through the right hand vermin plate.
6
Models:
308
309
556
557
559
561
Models:
1004
1005
Knockout
Air intake hose
Knockoutremoved and
protective grommet fitted.
Air intake hose
!
When installing Models
1004 and1005 heater the combustion air hose is of a larger diameter. A knock-out is provided in the vermin
plate that
MUST
be removed and a protective grommet fitted
MUST
be before the hose can be passed
through the vermin plate. The combustion air hose for the heater is attached to the large diameter combustion
air inlet.
CAUTION
Secure the combustion air hose to the combustion air inlet with cable tie supplied with the
heater. Air hose connections
MUST
be made and checked in accordance with these instructions.
Improper connections may result in dangerous situations. The rubber cap (when fitted) is
designed to fit both the left and right hand combustion air inlet and
MUST
cover the air inlet not
in use.
WARNING
AT NO TIME MUST THE ‘AIR INTAKE’ HOSE BE CUT OR SHORTENED.
7.
7
8
Air intake
hose
Air intake
hose
Move the right hand vermin plate along the hose until it is flush against the wall, then secure in place with
three of the nine screws provided.
8.
Screw the left hand vermin plate to the right hand vermin plate (when overlapped correctly the holes in
both plates will be aligned) using three of the nine screws provided. Then use the remaining three of the nine
screws provided to fix the remainder of the left hand vermin plate to the wall.
9. Make the heater exhaust connections in accordance with the section "Connecting Heater Exhaust" on page
28.
At no time MUST the ‘Air intake hose’ be cut or shortened.
CAUTION
Heater exhaust connections at the heater
MUST
be made and checked in accordance with
these instructions. Improper connections may result in dangerous situations, for example, the
dispersion of combustion products in the space being heated.
10. Install the back cover kit and fasten the heater and back cover kit to the internal wall surface.
11.
Commission the heater in accordance with the manufacturer instructions supplied with the heater.