Rinnai 11 ES_FIM
27mm
31mm
Minimum 70mm
• EXTERNAL WALL
• IN-WALL
• UNDER FLOOR
• SIDEWAYS
SIDEWAYS
IN-WALL
EXTERNAL WALL
UNDER FLOOR
DIRECT
• DIRECT
• DIRECT EXTENDED
Cut to correct
length & discard
DIRECT EXTENDED
Cut to correct
length & discard
Cut to correct
length & discard
A
A
A
See note 1.
Note 1. When cutting the flue transition for joining to other components the minimum total length is
NOT
to be less than 300mm!
Note 2. A Condensate trap
MUST
be used at this point.
Note 3. Use of a flue transition fitted with a sideways flue terminal extension, will count as one of the
THREE (3)
allowed bends of a flue run.
Note 4. Where stipulated a
Minimum 2°
fall is required to ensure correct drainage of condensation formed in the discharge flue.
IMPORTANT
See Note 4.
Min 2° fall towards
the flue Terminal
!
See Note 4.
Min 2° fall towards
the flue Terminal
!
See Note 4.
Min 2° fall towards
the flue Terminal
!
See Note 4.
Min 2° fall towards
the flue Terminal
!
See Note 4.
Min 2° fall towards
the flue Terminal
!
See Note 4.
Min 2° fall towards
the appliance
!
See Note 4.
Min 2° fall towards
the appliance
!
Cut to correct
length & discard
!
See note 3.
!
See note 3.
!
See note 3.
!
See note 2.
!
See note 1.
!
See note 1.
!
See note 1.
!
See note 1.
!
See note 3.
!
See note 2.
!