REU-2532W Series
71
Rinnai
Using a voltage meter set on the 200 ohm scale, you should have a resistance reading of 26 ~ 30 ohms
through each of these heaters. The heater located on the heat exchanger piping should have a resistance
reading of 81 ~ 86 ohms and the one located in the water flow sensor valve has a resistance reading of 16 ~
19 ohms. Voltage throughout this circuit should be 120 VAC.
(3) Amp Fuses:
This unit has two inline (3) amp glass fuses. Remove the fuse and check continuity through it. If you have
Continuity through the fuse, it is good. If you can not read continuity, the fuse is blown and must be replaced.
Wiring Diagram:
REU2532-W