REU-2532W Series
39
Rinnai
2) Is the flame rod normal ? Error “72” is displayed
Checking the flame rod.
a.
# Detach the flame rod terminal C
1
, and
re-attempt operation.
(“72 is displayed)
Proceed to check item 3 below.
(no “72” displayed)
Inspect flame rod wiring for current leak and
inspect flame rod for carbon build-up.
Measure resistance between the flame rod
Terminal C
1
and the appliance earth.
Normal:
1 M
Ω
or more.
If normal, replace the PCB unit.
Faulty:
Replace the flame rod.
See page 43 for additional information and
reading pertaining to the flame rod.
3) Is the water temperature thermistor normal ?
If error “32” is displayed, check the water
temperature thermistor.
a.
# Disconnect connectorB
5
, and measure
resistance of the white ~ white wires.
Resistance
>
1 M
Ω
= open circuit.
Resistance < 1
Ω
= short circuit.
Normal:
Proceed to check item 4 on the
next page.
Faulty:
Replace the water temperature
thermistor.
See page 44 for additional information and
reading pertaining to the temperature
thermistor. .
Summary of Contents for Continuum REU2532-W Series
Page 8: ...REU 2532W Series 8 Rinnai 3 Dimensions...
Page 9: ...REU 2532W Series 9 Rinnai 4 Installation Piping recommendation...
Page 16: ...REU 2532W Series 16 Rinnai 9 Cut way Diagram REU 2532 FFU Series...
Page 17: ...REU 2532W Series 17 Rinnai 10 Schematic Diagram REU 2532W Series...
Page 26: ...REU 2532W Series 26 Rinnai 15 Time Charts External Unit...
Page 27: ...REU 2532W Series 27 Rinnai...
Page 35: ...REU 2532W Series 35 Rinnai 20 REU 2532W Series Wiring...
Page 36: ...REU 2532W Series 36 Rinnai 21 Block Diagram...
Page 60: ...REU 2532W Series 60 Rinnai 26 EXPLODED VIEW CABINET...
Page 61: ...REU 2532W Series 61 Rinnai EXPLODED VIEW INTERNALS...
Page 62: ...REU 2532W Series 62 Rinnai EXPLODED VIEW INTERNALS...
Page 63: ...REU 2532W Series 63 Rinnai EXPLODED VIEW ELECTRICAL...