REU-2532W Series
20
Rinnai
(Switches 3,4, & 5) Temperature Adjustment Switches.
Switches #3, 4, and 5 are used to set fixed temperatures with or
without the remote keypads. Contact Rinnai for dip switch settings when changing the unit’s PC board or setting up special
applications.
Failure to set dip switches to the proper position will result in damage to the unit, property damage,
personal injury or death. DO NOT, adjust switches unless you have written permission directly from Rinnai. Call
1(800)621-9419
to set-up a special training class pertaining to dip switch functions.
(Switch #6) Flow Switch and Temperature Adjustments.
Rinnai offers a flow switch that can serve as an anti-scald
device. This switch is installed in-line with each bathroom. Therefore, if someone was using water above 120
°
F and a tap
was turned on in one of the bathrooms, the unit would automatically default back to 120
°
F to prevent scalding. When dip
switch #6 is set to the
“ON”
position this function is activated. At the present time this switch is not used in the U.S.
market, due to anti-scald devices and/or pressure balancing valves presently being used in our market.
(Switches 7& 8) Low/High Fire Combustion Control Switches.
Dip switch # 7 is used to place the unit into forced low
fire when checking and/or setting manifold gas pressures. Dip switch #7 and #8 are used to place the appliance into forced
high fire. Before making any adjustments to these switches, please ensure you follow the gas pressure setting procedure
found in this manual.
“SW2” row of Dip Switches
1. Gas type (Used only when replacing PCB or converting unit)
2. Lime control switch activated or de-activated.
3. Plus three degrees or plus six degrees differential.
4. Type of unit. (Residential or commercial)
(SW2) Explanation of SW2 row of Dip Switches
(Switch #1) Gas Type Switch.
When set to the
“OFF” position
the unit is setup to operate on propane gas, in the
“ON”
position it is setup for natural gas.
(Switch #2) Lime Control Switch.
Set dip switch #2 to the
“OFF”
position to activate the lime control function. To
deactivate this function place this switch in the
“ON”
position.
(#3) Temperature Differential Switch.
The temperature of the outgoing water is constantly monitored by the outlet
temperature thermistor. If the outlet water temperature rises to more than 5.4
°
F above the preset temperature, the burner
will automatically go out when dip switch #3 is in the
“OFF”
position. The burner will ignite again once the outlet water
temperature falls below the preset temperature. If this switch is set to the
“ON”
position it will allow a 10.8
°
F rise.
(Switch #4) Type of Unit.
Danger; do not adjust this dip switch.
Adjusting this will result in damage to the unit,
property damage, personal injury or death.
Summary of Contents for Continuum REU2532-W Series
Page 8: ...REU 2532W Series 8 Rinnai 3 Dimensions...
Page 9: ...REU 2532W Series 9 Rinnai 4 Installation Piping recommendation...
Page 16: ...REU 2532W Series 16 Rinnai 9 Cut way Diagram REU 2532 FFU Series...
Page 17: ...REU 2532W Series 17 Rinnai 10 Schematic Diagram REU 2532W Series...
Page 26: ...REU 2532W Series 26 Rinnai 15 Time Charts External Unit...
Page 27: ...REU 2532W Series 27 Rinnai...
Page 35: ...REU 2532W Series 35 Rinnai 20 REU 2532W Series Wiring...
Page 36: ...REU 2532W Series 36 Rinnai 21 Block Diagram...
Page 60: ...REU 2532W Series 60 Rinnai 26 EXPLODED VIEW CABINET...
Page 61: ...REU 2532W Series 61 Rinnai EXPLODED VIEW INTERNALS...
Page 62: ...REU 2532W Series 62 Rinnai EXPLODED VIEW INTERNALS...
Page 63: ...REU 2532W Series 63 Rinnai EXPLODED VIEW ELECTRICAL...